Klin Monbl Augenheilkd 2004; 221(1): 40-46
DOI: 10.1055/s-2003-812636
Klinische Studie
© Georg Thieme Verlag Stuttgart · New York

Heparinbeschichtete Polymethylmethacrylat- und faltbare hydrophobe Acrylatintraokularlinsen bei Kataraktpatienten mit erworbenem Immundefektsyndrom und CMV-Retinitis

Heparin Surface-Modified Poly(methylmethacrylate) and Foldable Hydrophobic Acrylic Intraocular Lenses in Cataract Patients with Acquired Immune Deficiency Syndrome and CMV-RetinitisSusanne  Krieglsteiner1 , Herrmann  O. C.  Gümbel1, 2 , Thomas  Kohnen1
  • 1Johann-Wolfgang-Goethe-Universität, Zentrum für Augenheilkunde, Frankfurt am Main (Leiter: Prof. Dr. C. Ohrloff)
  • 2Bundeswehrkrankenhaus, Abteilung für Augenheilkunde, Ulm (Leiter: Priv.-Doz. Dr. H. O. C. Gümbel)
Further Information

Publication History

Eingegangen: 16. Juli 2003

Angenommen: 16. Oktober 2003

Publication Date:
27 January 2004 (online)

Zusammenfassung

Hintergrund: Bei HIV-Patienten mit nekrotisierender Retinitis sind bei der Kataraktoperation ein gut verträgliches Linsenmaterial sowie eine minimal invasive Operationsmethode zur Vermeidung postoperativer Komplikationen erforderlich. Heparinbeschichtete (HSM) Polymethylmethacrylat(PMMA)-IOL sowie Intraokularlinsen aus hydrophobem Acrylat gehen mit einer geringeren postoperativen Entzündung als Intraokularlinsen aus herkömmlichen Materialien einher [6] [13] [14]. Methoden: In einer randomisierten, prospektiven klinischen Studie wurden bei insgesamt 18 Patienten 7 HSM-IOL (Pharmacia 811 C) über eine sich selbst verschließende Skleratunnelinzision und 11 faltbare hydrophobe Acrylat-IOL (Alcon-Acrysof-MA60BM) über eine sich selbst verschließende Limbustunnelinzision durch denselben Chirurgen implantiert. 7 der 18 Augen waren bei Beginn der Studie silikonölgefüllt, 1 Patient der Acryl-Gruppe entwickelte im Laufe der Studie eine Amotio und erhielt ebenfalls eine Silikonölendotamponade. Visus, Intraokulardruck, Kontrastsensitivität, intraokularer Reizzustand sowie die Entwicklung eines Nachstares wurden dokumentiert und ausgewertet. Der Nachbeobachtungszeitraum betrug 1 Jahr. Ergebnisse: Augen mit Acrysof-IOLs waren mit niedrigeren, aber nicht statistisch signifikanten Laserflarewerten (Photon counts/ms) assoziiert als solche mit HSM-IOLs: prä- (90,18 ± 54,7 vs. 73,92 ± 6,44) und 3 Monate post-OP (69,06 ± 8,27 vs. 55,03 ± 7,75). 6 von 7 Augen mit HSM-IOL und 3 Augen aus der Acrysof-Gruppe sowie alle silikonölgefüllten Augen entwickelten eine dichte Nachstarmembran, 6 Augen zeigten eine leichtgradige, 2 Augen keine Nachstarbildung. Die YAG-Kapsulotomie führte in keinem Fall zu einer Visusverbesserung, ermöglichte aber wieder eine bessere Untersuchung der Netzhaut. Bei deutlich besserem Ausgangsvisus Acryl-IOL (Hbw-0,4), HSM-PMMA-IOL (Nulla lux - 0,1) erreichten Augen mit Acryl-IOL auch einen deutlich besseren postoperativen Visus als solche mit HSM-PMMA-IOL (0,05 - 0,6) vs. (Nulla lux - 0,1). Die Kontrastsehprüfung zeigte nur geringfügige Verbesserungen nach dem Eingriff in beiden Gruppen. Die Intraokulardruckwerte betrugen vor dem Eingriff durchschnittlich 13,86 (PMMA) vs. 14,82 mm Hg (Acrysof) und 3 Monate später 14,4 vs. 12,89 mm Hg. Schlussfolgerung: Die von uns untersuchten Parameter zeigten keinen statistisch signifikanten Unterschied zwischen heparinbeschichteten IOLs (Pharmacia 811 C) und IOLs aus hydrophobem Acrylat (Alcon-Acrysof-MA60BM) bei Kataraktpatienten mit AIDS. Da faltbare hydrophobe Acrylat-IOLs über eine sich selbst verschließende, unblutige Tunnelinzision implantiert werden können und mit weniger Nachstarausbildung einhergehen, bevorzugen wir diesen Linsentyp bei der Kataraktchirurgie von AIDS-Patienten.

Abstract

Background: In HIV-positive patients with necrotising retinitis, well-tolerated lens material as well as minimal invasive surgery to avoid postoperative complications are imperative. Heparin surface-modified PMMA-IOLs as well as acrylic IOLs are associated with less postoperative inflammation than conventional intraocular lenses [6] [13] [14]. Methods: In this randomised prospective clinical trial 18 patients received 7 HSM-IOLs through a self-sealing scleral tunnel and 11 foldable Acrysof-IOLs through a self-sealing limbal tunnel incision by the same surgeon. 7 of the 18 eyes were silicone oil-filled before cataract surgery, one eye received oil after the IOL implantation. Visual acuity, intraocular pressure, contrast sensitivity, intraocular inflammation and posterior capsule opacification were assessed. The follow-up period was 1 year. Results: Eyes with Acrysof-IOLs were associated with lower, but not statistically significant, laser flare photometry values (photon counts/ms) than those with HSM-IOLs pre- (90.18 ± 54.7 vs. 73.92 ± 6.44) and 3 months post-surgery (69.06 ± 8.27 vs. 55.03 ± 7.75). 6 of the 7 eyes with HSM-IOL and 3 eyes of the Acrysof-group developed a dense posterior capsule opacification (PCO), 2 eyes had no and 6 eyes only a distinct PCO. YAG capsulotomy did not improve visual acuity in any case but retinal examination was again possible. Eyes with Acryl-IOL showed pre- and postoperatively a better visual acuity than eyes with HSM-IOL („hand movement” - 0.4 vs. „no light perception” - 0.1 pre- and 0.05 - 0.6 vs. „no light perception” - 0.1 3 months postoperatively. Contrast sensitivity testing (Vistech method) could be performed in the PMMA-group preoperatively only in 1 eye (A1), in the Acryl-group in 2 eyes (A4, B4, C2, D2) and revealed postoperatively „no contrast vision” - A1, B2, C1 vs. „no contrast vision” - A2, B2, C3, D1, E1. The intraocular pressure was preoperatively 13.86 mm Hg (PMMA) vs. 14.82 mm Hg (Acrysof) and 14.4 mm Hg vs. 12.89 mm Hg 3 months post surgery. Conclusion: In the parameters we observed there was no statistical significant difference between heparin-surface modified (Pharmacia 811 C) and hydrophobic acrylic IOLs (Alcon Acrysof MA60BM) in patients with AIDS. As foldable Acrysof-IOLs can be implanted through a self-sealing bloodless tunnel incision and are associated with less posterior capsule opacification we prefer this IOL type in cataract surgery of AIDS patients.

Literatur

  • 1 Davis J L, Serfass M S, Lai M Y, Trask D K, Azen S P. Silicone oil in repair of retinal detachments caused by necrotizing retinitis in HIV infection.  Arch Ophthalmol. 1995;  113 1366-1368
  • 2 Elvira J C, Huseo J R, Martinez-Toldos J, Mengual E, Artola A. Induced endothelial cell loss in phacoemulsification using topical anesthesia plus intracameral lidocaine.  J Cataract Refract Surg. 1995;  25 640-642
  • 3 Garweg J G. Veränderungen der hinteren Augenabschnitte bei HIV-Infektion nach Einführung der hochaktiven antiretroviralen Therapie (HAART).  Klin Monatsbl Augenheilkd. 2000;  216 68-74
  • 4 Gulick R M. Current antiretroviral therapy: an overview.  Qual Life Res. 1997;  6 471-474
  • 5 Hayashi H, Hayashi K, Nakao F. Quantitative comparison of posterior capsule opacification after Polymethylmethacrylate, Silicone and soft acrylic intraocular lens implantation.  Arch Ophthalmol. 1998;  116 1579-1582
  • 6 Hollick E J, Spalton D J, Ursell P G, Pande M V. Biocompatibility of poly(methyl methacrylate), silicone and AcrySof intraocular lenses: randomized comparison of the cellular reaction on the anterior lens surface.  J Cataract Refract Surg. 1998;  24 361-366
  • 7 Kohnen T, Lambert R J, Koch D D. Incision sizes for foldable intraocular lenses.  Ophthalmology. 1997;  104 1277-1286
  • 8 Mester U, Strauss M, Grewing R. Biocompatibility and blood-aqueous barrier impairment in at risk eyes with heparin-surface-modified or unmodified lenses.  J Cataract Refract Surg. 1998;  24 380-384
  • 9 Montaner J S, Hogg R, Raboud J, Harrigan R, O'Shaughnessy M. Antiretroviral treatment in 1998 (Review).  Lancet. 1998;  352 919-922
  • 10 Muller-Jensen K, Fischer P. Minimizing induction of astigmatism in preoperative spherical cornea a. by mini-incision surgery with foldable IOL and b. by corneal tunnel incision with limbal relaxing incision.  Klin Monatsbl Augenheilkd. 1999;  215 158-162
  • 11 Ohrloff C. Die Bedeutung der intakten Hinterkapsel für den Glaskörper.  Klin Monatsbl Augenheilkd. 1994;  205 181-186
  • 12 Oner F H, Gunene U, Ferliel S T. Posterior capsule opacification after phacoemulsification: foldable acrylic versus poly(methyl methacrylate) intraocular lenses.  J Cataract Refract Surg. 2000;  5 722-726
  • 13 Tognetto D, Toto L, Minutola D, Ballone E, Nicola M di, Mascio R Di, Ravalico G. Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study.  Graefe's Arch Clin Exp Ophthalmol. 2003;  241 625-630
  • 14 Umezawa S, Shimizu K. Biocompatibility of surface-modified intraocular lenses.  J Cataract Refract Surg. 1993;  19 371-374
  • 15 Whitcup S M. Cytomegalovirus retinitis in the era of highly active antiretroviral therapy.  JAMA. 2000;  283 653-657
  • 16 Ygge J, Wenzel M, Philipson B, Fagerholm P. Cellular reactions on Heparin Surface-modified versus regular PMMA lenses during the first postoperative month.  Ophthalmology. 1990;  97 1216-1223

Priv.-Doz. Dr. med. Thomas Kohnen

Oberarzt der Augenklinik Johann-Wolfgang-Goethe-Universität · Klinik für Augenheilkunde

Theodor-Stern-Kai 7

60590 Frankfurt am Main

Phone: 069/6301-6739

Fax: 069/6301-3893

Email: Kohnen@em.uni-frankfurt.de

    >