Abstract
The human pupil represents an easily accessible target organ of the central and peripheral functions of the autonomous nervous system. As advances in modern electronic technology improved recording and evaluation techniques (the measurement of pupil diameter and pupil reactions) gained increased importance in clinical psychophysiological diagnostics. In 1902, Dupont, and in 1910, Weiler, tried to measure the pupil diameter by means of a scale. For this purpose the pupil was observed directly by an optical system. After the development of photography, it was possible to obtain pictures of the pupil diameter [1,2]. Later, movie cameras that registered absolute measurement of diameter and for demonstration of continuous changes in size, were and are used today [3, 4, 5]. Recently, electronic devices based on infrared light illumination were developed, such as the Whittaker Corporation TV-Pupillometer. It therefore became possible to measure pupillary reactions more objectively, economically and precisely. The aim of the present paper is to outline our developed methodology, to inform about reliability and validity, and finally, to make proposals for application to a psychiatric clinic.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Dupont M (1902) Instruments pour provoquer et measurer le reflexe pupillaire. Rev Gen Opthalmol 21: 515–516
Weiler K. (1910) Untersuchungen der Pupille und der Irisbewegungen beim Menschen. Z Neurol 201
Markworth NH (1968) The wide-angle reflection eye camera for visual choice and pupil size. Perception and Psychophysics 3: 32–34
Hess EH (1972) Das Sprechende Auge. Die Pupille verrät Verborgene Reaktionen. Kindler Verlag,München
Hess EH (1972) Pupillometries. In: Greenfield NS, Sternbach RA (eds) Handbook of Psychophysiology,New York Holt, Rinehard & Winston
Ishikawa S, Oono S, Hitaka H (1976) Drugs affecting the iris muscle. In: Drugs and Ocular Tissue, Dikstein, S (ed) Basel: Karger pp 288–382
Beatty J (1982) Task-evoked pupillary responses, processing load, and the structure of processing resources. Psychol Bull 91: 276–292
Grünberger J, Linzmayer L, Cepko H, Saletu B (1987) Lichtevozierte dynamische Pupillometrie zur Differenzierung psychotroper Substanzen. Arzneim Forsch 3: 357–360
Grünberger J, Linzmayer L, Witek R, Saletu B (1987) Faktorenanalytische Untersuchungen und Reliabilitätsbestimmung der statischen und dynamischen Pupillometrie. Wr Med Wschr 7, 8: 135–139
Grünberger J, Linzmayer L, Saletu B (1984) Psychodiagnostik mit Hilfe psychophysiologischer Verfahren. Wien Med Wschr 2: 29–35
Kahnemann U, Beatty J (1966) Pupil diameter and load on memory. Science 154: 1583–1585
Grünberger J, Linzmayer L, Saletu B, Stöhr H (1984) Mikrocomputer im Einsatz bei Routineuntersuchungen und Forschungsaufgaben im Bereich der klinischen Psychodiagnostik. Biomed Technik 29: 283–288
Lowenstein O, Loewenfeld IE (1962) The pupil. In: Davson H (ed) The Eye, Bd 3, New York: Muscular Mechanisms
Grünberger J, Linzmayer L, Saletu B, Stöhr H (1984) Zur Methodologie der Pupillenmessung. Psychiatr Clin 3: 157–164
Grünberger J, Linzmayer L, Gathmann P, Saletu B (1985) Computerassistierte „statische“ und lichtevozierte „dynamische“ Pupillometrie bei psychosomatischen Patienten. Wien Klin Wschr 20: 775–781
Grünberger J, Linzmayer L, Cepko H, Saletu B (1986) Pupillometrie im psychopharmakologischen Experiment. Arzneim Forsch 1: 141–146
Rubin LS (1964) Autonomic dysfunction concomitant of neurotic behaviour. J Nerv Ment Dis 138: 558–574
Grünberger J, Linzmayer L, Küfferle B, Saletu B (1986) Pupillometrie bei schizophrenen Patienten. In: Keup W, Biologische Psychiatric Springer, New York Heidelberg Berlin, S. 199–211
Grünberger J, Linzmayer L, Saletu B, Lesch OM (1989) Klinische psychophysiologische Diagnostik bei ambulanten Alkoholikern: Statische und lichtevozierte dynamische Pupillometrie. Wr Zschr f Suchtforschung 12 Nr. 1/2: 53–62
Aghajanian GK (1978) Tolerance of locus ceruleus neurons to morphine and suppression of withdrawal response to clonidin. Nature 276: 186–187
Grünberger J, Linzmayer L, Fodor G, Presslich O, Praitner M, Loimer N (1990) Static and dynamic pupillometry for determination of the course of gradual detoxification of opiate-addicted patients. Eur Arch Psychiatry Clin Neurosci 240: 109–112
Grünberger J, Linzmayer L, Dietzel M, Saletu B. The effect of biologically active light on the noo-and thymopsyche and on psychophysiological parameters in healthy volunteers
Grünberger J, Linzmayer L, Pakesch G, Pfersmann D, Guggenberger K, Loimer N (1989) Psychometrische und psychophysiologische Untersuchungen bei AIDS-Patienten mit Berücksichtigung des „Denivellierungsyndroms“ Niveausenkung. Wr Med Wschr 8: 175–178
Grünberger J, Linzmayer L, Gasic S, Saletu B (1988) Computerassistierte statische und dynamische Pupillometrie zur Charakterisierung des trizyklischen Antidepressivums Cianopramin. Arz-neim Forsch 3: 383–387
Sitaram N, Jones D, Kewala S, Bell J, Stevenson J, Gershon S (1983) Pharmacology of the human iris: Development and use of challenge strategies in the study of antidepression response. Prog Neuro Psychopharmacol & Biol Psychiatry 7: 273–286
Tryon WK (1975) Pupillometry: A survey of sources of variation. Psychophysiology 23: 90–93
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2003 Springer-Verlag Wien
About this chapter
Cite this chapter
Grünberger, J. (2003). Psychophysiologie. In: Pupillometrie in der klinisch- psychophysiologischen Diagnostik. Springer, Vienna. https://doi.org/10.1007/978-3-7091-6032-9_3
Download citation
DOI: https://doi.org/10.1007/978-3-7091-6032-9_3
Publisher Name: Springer, Vienna
Print ISBN: 978-3-211-83854-9
Online ISBN: 978-3-7091-6032-9
eBook Packages: Springer Book Archive