Annular rupture presents a rare but potentially fatal complication of transcatheter aortic valve implantation (TAVI). Although it can be subtle and subclinical in presentation, most severe forms present with hemodynamic instability and represent true emergencies requiring a more invasive treatment, even conventional surgery. We present a case of successful treatment of annular rupture by left ventricular outflow tract patch and surgical aortic valve replacement.
Literatur
1.
Zurück zum Zitat Walther T, Webb JG, Schuler G, et al. Perioperative results and complications of 15964 transcatheter aortic valve replacements: prospective data from the GARY registry. J Am Coll Cardiol. 2015;65(20):2173–80.CrossRefPubMed Walther T, Webb JG, Schuler G, et al. Perioperative results and complications of 15964 transcatheter aortic valve replacements: prospective data from the GARY registry. J Am Coll Cardiol. 2015;65(20):2173–80.CrossRefPubMed
2.
Zurück zum Zitat Lange R, Bleiziffer S, Piazza N, et al. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg. 2011;40(5):1005–13. Lange R, Bleiziffer S, Piazza N, et al. Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg. 2011;40(5):1005–13.
3.
Zurück zum Zitat Rezq A, Basavarajaiah S, Latib A, et al. Incidence, management, and outcomes of cardiac tamponade during transcatheter aortic valve implantation: A single-center study. J Am Coll Cardiol Intv. 2012;5(12):1264–72.CrossRef Rezq A, Basavarajaiah S, Latib A, et al. Incidence, management, and outcomes of cardiac tamponade during transcatheter aortic valve implantation: A single-center study. J Am Coll Cardiol Intv. 2012;5(12):1264–72.CrossRef
4.
Zurück zum Zitat Wu Y, Vallely M, Ng MKC. Valve-in-valve implantation for aortic annular rupture complicating transcatheter aortic valve replacement (TAVR). J Invasive Cardiol. 2013;25(8):409–10. Wu Y, Vallely M, Ng MKC. Valve-in-valve implantation for aortic annular rupture complicating transcatheter aortic valve replacement (TAVR). J Invasive Cardiol. 2013;25(8):409–10.
5.
Zurück zum Zitat Pasic M, Unbehaun A, Buz S, Drews T, Hetzer R. Annular rupture during transcatheter aortic valve replacement: classification, pathophysiology, diagnostics, treatment approaches and prevention. JACC Cardiovasc Interv. 2015;8(1):1–9.CrossRefPubMed Pasic M, Unbehaun A, Buz S, Drews T, Hetzer R. Annular rupture during transcatheter aortic valve replacement: classification, pathophysiology, diagnostics, treatment approaches and prevention. JACC Cardiovasc Interv. 2015;8(1):1–9.CrossRefPubMed
6.
Zurück zum Zitat Barbanti M, Yang T‑H, Rodes Cabau J, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128(3):244–53.CrossRefPubMed Barbanti M, Yang T‑H, Rodes Cabau J, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128(3):244–53.CrossRefPubMed
7.
Zurück zum Zitat Pasic M, Unbehaun A, Dreysse S, et al. Rupture of the device landing zone during transcatheter aortic valve implantation. A life-threatening but treatable complication. Circ Cardiovasc Interv. 2012;5(3):424–32.CrossRefPubMed Pasic M, Unbehaun A, Dreysse S, et al. Rupture of the device landing zone during transcatheter aortic valve implantation. A life-threatening but treatable complication. Circ Cardiovasc Interv. 2012;5(3):424–32.CrossRefPubMed
8.
Zurück zum Zitat Tommaso CL, Bolman RM 3rd, Feldman T, et al. Multisociety (AATS, ACCF, SCAI, and STS) expert consensus statement: operator and institutional requirements for transcatheter valve repair and replacement, Part 1: transcatheter aortic valve replacement. Ann Thorac Surg. 2012;93(6):2093–110.CrossRefPubMed Tommaso CL, Bolman RM 3rd, Feldman T, et al. Multisociety (AATS, ACCF, SCAI, and STS) expert consensus statement: operator and institutional requirements for transcatheter valve repair and replacement, Part 1: transcatheter aortic valve replacement. Ann Thorac Surg. 2012;93(6):2093–110.CrossRefPubMed
Metadaten
Titel
Successful treatment of annular rupture during transcatheter aortic valve implantation
verfasst von
Daniel Unic, MD
Zeljko Sutlic, MD, PhD
Boris Starcevic, MD, PhD
Nikola Bradic, MD
Davor Baric, MD, PhD
Igor Rudez, MD, PhD
Publikationsdatum
01.04.2017
Verlag
Springer Vienna
Erschienen in
Wiener klinische Wochenschrift / Ausgabe 7-8/2017
Print ISSN: 0043-5325
Elektronische ISSN: 1613-7671
DOI
https://doi.org/10.1007/s00508-016-1102-x

Weitere Artikel der Ausgabe 7-8/2017

Wiener klinische Wochenschrift 7-8/2017 Zur Ausgabe