Minim Invasive Neurosurg 2001; 44(4): 202-204
DOI: 10.1055/s-2001-19938
Original Article
Georg Thieme Verlag Stuttgart · New York

Measurement of Median Nerve Blood Flow during Carpal Tunnel Release with Laser Doppler Flowmetry

O.  Soejima1 , H.  Iida2 , M.  Naito1
  • 1Department of Orthopaedic Surgery, Fukuoka University School of Medicine, Fukuoka, Japan
  • 2Iida Orthopaedic Clinic, Miyazaki, Japan
Further Information

Publication History

Publication Date:
01 February 2002 (online)

Abstract

Eight consecutive median nerves in eight patients with clinical carpal tunnel syndrome were prospectively examined by non-contact laser Doppler flowmetry before and after undergoing carpal tunnel release. Before performing carpal tunnel release, the difference in the median nerve blood flow between the values at the distal and proximal portions to the transverse carpal ligament was statistically significant (p = 0.021). After carpal tunnel release, the median nerve blood flow both distal and proximal to the transverse carpal ligament increased by 1.5 and 1.3 times, respectively, compared to the flow prior to carpal tunnel release, however, only the difference at the distal portion to the transverse carpal ligament was statistically significant (p = 0.015). In this study, we directly measured the median nerve blood flow using non-contact laser Doppler flowmetry and thus demonstrated a significant difference in the median nerve blood flow between the values at the distal and proximal portions to the transverse carpal ligament before carpal tunnel release and a significant increase in the nerve blood flow only at the distal portion to the transverse carpal ligament after surgery. This technique is thus considered to be an easy and reproducible way to intraoperatively evaluate the nerve blood flow in real time during the release of entrapment neuropathies.

References

  • 1 Gelberman R H, Hergenroeder P T, Hargens A R, Lundborg G N, Akeson W H. The carpal tunnel syndrome: a study of carpal canal pressures.  J Bone Joint Surg. 1981;  63A 380-383
  • 2 Gellman H, Chandler D R, Petrasek J, Sie I, Adkins R, Waters R L. Carpal tunnel syndrome in paraplegic patients.  J Bone Joint Surg. 1988;  70A 517-519
  • 3 Szabo R M, Chidgey L K. Stress carpal tunnel pressures in patients with carpal tunnel syndrome and normal patients.  J Hand Surg. 1989;  14A 624-627
  • 4 Kongsholm J, Olerud C. Carpal tunnel pressure in the acute phase after Colles' fracture.  Arch Orthop Trauma Surg. 1986;  105 183-186
  • 5 Barone C M, Jimenez D F, Frempog-Bodeau A. Blood-flow measurements of injured peripheral nerves by laser Doppler flowmetry.  J Reconstr Microsurg. 1992;  8 319-323
  • 6 Seiler 3d J G, Milek M A, Carpenter G K, Swiontkowski M F. Intraoperative assessment of median nerve blood flow during carpal tunnel release with laser Doppler flowmetry.  J Hand Surg. 1989;  14A 986-991

O. SoejimaM. D., Assistant Professor 

Chief, Hand Surgery Service · Department of Orthopaedic Surgery ·
Fukuoka University School of Medicine

7-45-1, Nanakuma, Jonan-ku

Fukuoka 814-0180

Japan

Phone: +81-92-801-1011

Fax: +81-92-864-9055

Email: osoejima@cis.fukuoka-u.ac.jp

    >