Skip to main content

Hemoperfusion: technical aspects and state of the art

Abstract

Background

Blood purification through the removal of plasma solutes by adsorption to beads of charcoal or resins contained in a cartridge (hemoperfusion) has a long and imperfect history. Developments in production and coating technology, however, have recently increased the biocompatibility of sorbents and have spurred renewed interest in hemoperfusion.

Methods

We performed a narrative assessment of the literature with focus on the technology, characteristics, and principles of hemoperfusion. We assessed publications in ex vivo, animal, and human studies. We synthesized such literature in a technical and state-of-the-art summary.

Results

Early hemoperfusion studies were hampered by bioincompatibility. Recent technology, however, has improved its safety. Hemoperfusion has been used with positive effects in chronic dialysis and chronic liver disease. It has also demonstrated extraction of a variety of toxins and drugs during episodes of overdose. Trials with endotoxin binding polymyxin B have shown mixed results in septic shock and are under active investigation. The role of non-selective hemoperfusion in sepsis or inflammation remains. Although new technologies have made sorbents more biocompatible, the research agenda in the field remains vast.

Conclusion

New sorbents markedly differ from those used in the past because of greater biocompatibility and safety. Initial studies of novel sorbent-based hemoperfusion show some promise in specific chronic conditions and some acute states. Systematic studies of novel sorbent-based hemoperfusion are now both necessary and justified.

Introduction

The removal on unwanted plasma solutes by direct adsorption has an established long history. However, early sorbent technology had major bioincompatibility problems (e.g., thrombocytopenia, leukopenia, hypoglycemia, hypocalcemia). This held back the development and clinical application of hemoperfusion. Sorbent biocompatibility, however, has improved triggering renewed interest, investigations, and application of hemoperfusion in clinical practice.

Hemoperfusion: characteristics and principles

Extracorporeal blood purification can be achieved by different mass separation processes [1]. Diffusion, as in standard hemodialysis (HD), convection as in hemofiltration or their combination as in hemodiafiltration (HDF) [2]. While these techniques are based on membrane separation, a third mechanism, solute adsorption, is based on mass separation by a solid agent (sorbent) [3]. As current dialysis techniques present limitations due to membrane permeability characteristic, extracorporeal hemoperfusion represents an additional option for blood purification.

Sorbents have been studied for many years. Initially, inorganic aluminosilicates (zeolites) and charcoal were utilized for various purposes. In the last 50 years, however, organic polymer ion exchange resins and finally synthetic porous polymers (styrene or acrylic acid based) have been applied to blood purification (Table 1) [4]. Thus, while hemoperfusion techniques initially caused important adverse reactions and had problems with safe storage and priming, recent more biocompatible sorbent materials have been safely utilized for hemoadsorption techniques in various clinical settings.

Table 1 Development of sorbents and application in extracorporeal therapies

Sorbents have a very large surface/volume ratio and a significant capacity to bind specific solutes thanks to weak ionic bonds, Wan der Waals forces, and strong hydrophobic bonds. They can be natural raw materials, or be synthetically produced [5]. Zeolites (alumina-silicates) are inorganic porous polymers with a level of porosity, derived from their crystal structure (today synthetically modulated to control the structure of the internal pore system). Porous carbons, instead, are cellulose-derived organic polymers prepared by controlled thermal oxidation. Finally, almost all polymerizable monomers can be built up into large molecules via a multitude of reactions, using divinylbenzene as a potent crosslinking substance. Monomers can be bi-functional (creating linear polymers) or multifunctional (creating a cross-linked network polymer structure). The latter is the intrinsic nature of the most recent synthetic sorbents that can be further functionalized by surface-coating with biocompatible polysulfone [6].

Today, adverse plasma-to-sorbent-induced reactions have become uncommon and can be prevented by plasma separation prior to circulation through the sorbent bed. After the sorbent cartridge, blood is reconstituted so that red cells, white cells, and platelets never meet the sorbent surface, and bio-incompatibility reactions are avoided [7]. Alternatively, the sorbent is made biocompatible by a specific coating process covering the particles with bio-layers that are well tolerated by blood cells [8].

Sorbents are generally produced in granules, beads, or fibers. They are solid particles with a diameter generally ranging between 50 µm and 1.2 cm. The surface-area-to-volume ratio (S/V) is extremely high with a surface area varying from 300 to 1200 m2/g. In addition, sorbents are classified according to the size of the pores of their inner structure as a) Macro-porous (Pore size > 500 Å), b) Meso-porous (Pore size 20–500 Å) and c) Micro-porous (Pore size < 20 Å). The requirements for an ideal sorbent material are reported in Table 2 [9].

Table 2 Requirements for ideal sorbent material and optimal cartridge design

Once the sorbent particles are produced, their packing into a device (cartridge) requires a tortuous pathway (sorbent bed) through which blood or any fluid phase must flow. Optimal packing density is generally between 35 and 55% of the available space. The optimal design of the cartridge depends on this factor and other factors listed in Table 2 [9].

When blood or plasma is circulated through the sorbent bed, removal of solutes by adsorption takes place on the surface of the beads. Maximum adsorption is achieved when equilibrium is reached, i.e., when the concentration of the marker solute at the outlet of the unit equals the concentration at the inlet. No theory for predicting adsorption curves has been universally embraced. Instead, laboratory experiments must be performed at fixed temperature (separation processes are energy intensive and affect entropy) for each liquid mixture and sorbent to provide sufficient data to derive specific plotting curves called adsorption isotherms.

At equilibrium, the following equation applies:

$$C_{{{\text{b}}({\text{initial}})}} \times V_{{\text{b}}} = \, \left( {C_{{{\text{b}}({\text{final}})}} \times V_{{\text{b}}} } \right) + \left( {C_{{\text{s}}} \times S} \right)$$

where Cb(initial) is the concentration of the solute at the beginning of the experiment; Vb is the total volume of the carrier fluid (constant during the experiment), Cb(final) is the concentration of the solute at the end of the experiment (when equilibrium takes place), Cs is the concentration of the adsorbate (mol/unit of sorbent mass), and S is the total mass of the sorbent available for mass transport.

Adsorption isotherms can be used to determine the amount of sorbent required to remove a given amount of solute. However, isotherms may differ with different unit design. This depends on the packing density of the sorbent, the length and inner diameter of the unit (cartridge), and the inter-particle distance and path tortuosity, all of which regulate the flow dynamics inside the unit. The flow characteristics through a sorbent bed are also governed by physical laws such as Darcy’s law and the Kozeny–Carman equation, which is used to calculate the pressure drop for a fluid flowing through a packed bed of solids. However, discussion of these additional laws and equations goes beyond the scope of this manuscript.

In practice, the adequacy of unit design can be evaluated by measuring its solute mass transfer zone (MTZ). The MTZ (expressed in cm) is represented by the distance between the point (cross section) where all sorbent material is saturated, and the point where zero adsorbate is present in the sorbent. Depending on flow distribution inside the unit, the MTZ may be very short (less than 1/3 of the unit length), equal to or longer than unit length. In the last two cases, a flow-through condition is experienced (i.e., a condition when solute is present at the outlet of the unit, this leaving behind some unused sorbent mass) [10].

The main goal of constructing an optimal sorbent cartridge is to obtain the maximum contact of the fluid phase with the entire amount of available sorbent. There are various steps, however, in such adsorption process:

  1. (a)

    External (interphase) mass transfer of the solute from the bulk fluid by convection through a thin film or boundary layer to the outer surface of the sorbent;

  2. (b)

    internal (intra-phase) mass transfer of the solute by pore diffusion from the outer surface of the adsorbent to the inner surface of the internal porous structure;

  3. (c)

    surface diffusion along the porous surface and

  4. (d)

    adsorption of the solute onto the porous surface.

During clinical use, the final kinetics also depend on the extracorporeal blood flow and the initial concentration of the marker molecule. These factors may result in earlier saturation or prolonged efficiency of the hemoperfusion unit [11].

The logic behind hemoperfusion

Why remove solutes directly from blood with sorbents

The concept that some disease states are associated with the presence of injurious molecules (solutes) in blood is well-established and the basis of life-saving treatments like dialysis. Some solutes are very large and can only be removed by plasma exchange. However, other toxic solutes are small enough to be removed by dialysis or by adsorption to sorbents beads [12]. Such coated sorbent beads can be packed into a cartridge to enable inclusion into an extracorporeal circuit. This process allows the contact of blood with the sorbent for a sufficient period to allow removal of target solutes with limited activation of the immune system [3]. This approach is attractive because it is direct, technically relatively simple, and theoretically efficient [13].

The plasma exchange or plasmafiltration option

Plasma exchange or plasma filtration [14] are techniques that enable the removal of most molecules present in plasma, spanning in size from any small solute to large protein such as globulins [15]. These techniques remove a broad array of molecules that are believed to be toxic as in sepsis [16] or severe liver failure [17]. However, removal is non-selective and simultaneous removal of a large array of potentially beneficial or necessary molecules (clotting factors, albumin, antibiotics, and protective antibodies) takes place. Consequently, replacement of such losses requires the administration of albumin and/or fresh frozen plasma, with the problem of cost and blood product consumption. Moreover, as therapy continues or becomes more intensive, it has the effect of removing the very “non-toxic” plasma administered to cover the losses of clotting factors. Thus, outside of specific situations [15], plasma exchange has not achieved widespread application.

The rationale for blood purification in “toxic states”

When key homeostatic organs (e.g., kidneys, liver, and immune system) malfunction, toxic solutes accumulate [18]. This provides the rationale for blood purification therapy. In the case of dialysis, this rationale has led to a life-saving therapy for millions of patients over the last 50 years. For liver failure or immune dysfunction; however, no equivalent therapy has yet been developed.

Nonetheless, the concept of blood purification therapy is supported by multiple ex vivo studies [19,20,21] and experimental animal studies [22, 23]. All show that a wide array of endogenous and exogenous toxins (including endotoxin, poisons and drugs) can be removed by blood purification techniques [24,25,26]. Such studies have also shown clinical and survival benefit in animal models. However, the efficiency of toxin removal with current systems may be inadequate in human disease [27] and animal studies do not offer a robust prediction of clinical effect.

Removal of protective solutes

A logical concern with blood purification by any technique that is not highly specific is that it will lead remove protective solutes (e.g., antibiotics or anti-inflammatory substances, protective cytokines, amino acids, macro- and micronutrients and other circulating potentially protective metabolites). Such removal might be as quantitatively important as the removal of toxins. However, in predominantly toxic states, the dominant view is that the accumulation of toxins likely outweighs that of protective molecules. Thus, any broad removal technique will remove more toxic than protective molecules [28]. It remains unclear whether this paradigm is true or not. Such uncertainty stems from the fact that we have a very limited understanding of such protective molecules. Thus, in sepsis, the only molecules we currently understand to be protective are antimicrobial drugs. However, while extensive clearance data exists for different forms of renal replacement therapy [29], the data for antibiotics and antifungal drugs removal during hemoperfusion is scant or absent.

Selective vs non-selective hemoperfusion in sepsis

Blood purification in sepsis has been a key area of investigation because of the view that soluble mediators of injury are a major contributor to morbidity and mortality in septic patients [30]. Such mediators appear to span a wide array of molecular size and are potentially amenable to removal by hemoperfusion. In the field of hemoperfusion in sepsis, two approaches have been developed, one based on selective targeting of a key molecule (e.g., endotoxin) and the other based on non-selective adsorption.

The concept of endotoxin adsorption has been based on several trials of the endotoxin-binding ability of polymyxin B as discussed in detail below [31].

The effectiveness of the broad adsorption strategy for sepsis, on the other hand, has not yet been tested in suitably designed multicenter randomized controlled trials. Thus, it lacks experimental and clinical robustness.

Nonetheless, two sorbent technologies have emerged: the Cytosorb cartridges [32, 33] and the Jafron HA cartridges series [34]. These sorbents have been used as rescue therapy in sepsis or as adjuvant therapy in sepsis [34] and experience has accumulated in terms of technique and safety [35]. However, that before substantial randomized controlled studies are designed and performed, more work is needed regarding what technical parameters (e.g., blood flow, cartridge size, length and composition and duration of use) define the optimal operative characteristics of such technology.

Technical aspects of hemoperfusion

The extracorporeal circuit needed for hemoperfusion requires vascular access with a double lumen catheter placed in a central vein. Hemoperfusion, however, can also be applied to the treatment of chronic patients and in combination with hemodialysis [36, 37] via arterio-venous fistulas. The extracorporeal circuit requires a hemodialysis or a continuous renal replacement therapy (CRRT) machine, or, in some cases, a simple blood pump with pressure alarms. Depending on the indications, the characteristics of the patient, the duration of the session, and the technique utilized, anticoagulation of the extracorporeal circuit can be optimized. In some patients, regional citrate anticoagulation can be employed, while in some others at high hemorrhagic risk, treatment can be performed without anticoagulation.

Due to the nature of the sorbent cartridges, the extracorporeal circuit may undergo modifications leading to different techniques.

Hemoperfusion (direct hemoadsorption) (HP): Blood is circulated by a pump through a sorbent unit (cartridge) and enters in direct contact with the sorbent particles [38] (Fig. 1). Blood flow may vary according to the size of the cartridge (100–250 ml/min). The extracorporeal circuit is anticoagulated with heparin or citrate.

Fig. 1
figure 1

Schematic configuration of direct hemoperfusion (HP). Qbi = Blood flow at the inlet of the unit; QfNet = net ultrafiltration

Hemoperfusion combined with dialysis/CRRT: The sorbent is utilized in combination with hemodialysis (HP-HD) or with CRRT (HP-CRRT). As shown in Fig. 2, the sorbent can be placed before or after the dialyzer [39].

Fig. 2
figure 2

Schematic configuration of hemoperfusion combined with hemodialysis (HP-HD) and hemoperfusion combined with continuous renal replacement therapy (HP – CRRT). Qbi = Blood flow at the inlet of the unit; Qbo = Blood flow at the outlet of the units; Qdi = Dialysate flow at the inlet of the dialyzer; Qdo = Dialysate flow at the outlet of the dialyzer; QfNet = net ultrafiltration

Plasmafiltration-adsorption: Plasma is separated from blood, circulated through the sorbent and reinfused into the circuit. This technique can be performed for a few hours (PFAD = plasmafiltration-adsorption) or over a prolonged period (CPFA = continuous plasmafiltration adsorption) (Fig. 3) [40].

Fig. 3
figure 3

Schematic configuration of plasmafiltration-adsorption (PFAD) or continuous plasmafiltration-adsorption (CPFA). Qbi = Blood flow at the inlet of the plasmafilter; Qbo = Blood flow at the outlet of the plasmafilter; Qpf = Plasmafiltrate flow; Qpr = Plasma Reinfusion flow; QfNet = net ultrafiltration

Plasmafiltration-adsorption combined with dialysis/CRRT: PFAD or CPFA can be combined with hemodialysis (PFAD-HD) or CRRT (CPFA-CRRT) to expand the efficiency of the treatment to small solutes such as urea and creatinine (Fig. 4) [16].

Fig. 4
figure 4

Schematic configuration of plasmafiltration-adsorption combined with hemodialysis (PFAD-HD) or continuous plasmafiltration-adsorption combined with continuous renal replacement therapy (CPFA-CRRT). Qbi = Blood flow at the inlet of the units; Qbo = Blood flow at the outlet of the units; Qpf = Plasmafiltrate flow; Qpr = Plasma Reinfusion flow; Qdi = Dialysate flow at the inlet of the dialyzer; Qdo = Dialysate flow at the outlet of the dialyzer; QfNet = net ultrafiltration

Double plasmafiltration molecular adsorption system (DPMAS): In some circumstances such as combined kidney and liver failure, different sorbent units with specific characteristics can be placed in the plasmafiltration circuit (Fig. 5). The nature of the sorbents and the characteristics of the cartridges depend on the indications and the degree of severity [41]

Fig. 5
figure 5

Schematic configuration of double plasmafiltration molecular adsorption system (DPMAS). Qbi = Blood flow at the inlet of the unit; Qbo = Blood flow at the outlet of the plasmafilter; Qpf = Plasmafiltrate flow; Qpr = Plasma Reinfusion flow; QfNet = net ultrafiltration

Hemoperfusion in combination with ECMO: In patients undergoing veno-venous or veno-arterial extracorporeal membrane oxygenation (VV-ECMO or VA-ECMO) hemoperfusion may be connected to the ECMO circuit. However, the sorbent and pressure gradients should be adjusted to achieve adequate flows while avoiding perturbations of the main circuit [42] (Fig. 6). Similar circuits can be created during cardiopulmonary bypass.

Fig. 6
figure 6

Schematic configuration of direct hemoperfusion combined with extracorporeal membrane oxygenation (HP-ECMO). Qbi HP = Blood flow at the inlet of the hemoperfusion unit; Qbo HP = Blood flow at the outlet of the hemoperfusion unit; Qbi ECMO = Blood flow at the inlet of the ECMO circuit; Qbo ECMO = Blood flow at the outlet of the ECMO circuit

All these approaches have been utilized with technical success and no major adverse events. However, several aspects still require technical and clinical studies. First, it is necessary to define solute kinetics and isotherms for specific solutes and different devices. Second, more work is needed to define the optimal duration of treatment in relation to blood blow, cartridge saturation, and clotting risk. Third, in the clinical environment, we need to correctly phenotype the patient, to identify criteria for initiation and cessation of hemoperfusion, to define optimal “adsorption dose” for a given patient and finally to identify marker molecules and clinical parameters to characterize the efficacy of the therapy and help design future trials. In their absence, the decision to use hemoperfusion remains based on clinical judgement and local expertise.

When to consider hemoperfusion

There are no established indications for hemoperfusion. However, several biologically and pathophysiological rational indications have emerged.

Intoxication

Several indications have been explored in relation to hemoperfusion in the setting of “intoxication.” As an example, they might include the treatment of intoxication with either a drug [43,44,45] (e.g., valproate, carbamazepine) or a toxic chemical (e.g., paraquat or organophosphates) [46, 47] or toxic natural products [48] (e.g., mushroom-related toxins). Unfortunately, no controlled studies exist. What is available, however, is information on extraction rate, clearance, and mass removal. Over the last decade, the hemoperfusion devices most commonly used for such treatment have been commercial Cytosorb® cartridges or the HA Jafron Biomedical series, with extraction rates from 20 to 90% [12].

Liver disease

There is very limited information or research in the use of hemoperfusion for severe liver failure (either acute or acute on chronic) even though there is a robust rationale for targeting ammonia or bilirubin in this setting [49]. However, there may be a role of hemoperfusion for the treatment of intractable cholestatic pruritus [49]. The available evidence is based on no controlled clinical trials and depends on sporadic case reports or small case series, thus preventing any conclusions [50].

Renal disease

A variety of end-stage renal failure-associated toxins are not adequately removed during dialysis justifying the combined use of resins in selected patients to address issues such as beta-2 microglobulin removal or uremic pruritus Initial reports are encouraging [36, 51].

Sepsis

Selective hemoperfusion

Several trials have addressed the possible effectiveness of hemoperfusion with polymyxin-bound membranes for the removal of endotoxin in patients with sepsis. These studies have consistently used the Toraymyxin™ (Toray Medical Co.Ltd., Tokyo, Japan) cartridge [52].

The first randomized trial (EUPHAS) was reported in 2009 and involved 64 patients with septic shock due to an abdominal cause. It randomized 34 patients to polymyxin (PMX) B hemoperfusion and 30 to conventional care [53]. EUPHAS reported physiological advantages on blood pressure, gas exchange, and vasopressor use with PMX but no change in the control population. In addition, PMX decreased time to mortality.

The second study was a multicenter randomized controlled trial of early PMX hemoperfusion in septic shock due to peritonitis [54]. It randomized 125 patients to PMX and 118 to conventional treatment. It found no benefit and a trend toward earlier time to mortality with PMX.

The third study was the EUPHRATES trial [55]. This trial compared PMX hemoperfusion to conventional therapy in 450 critically ill patients with septic shock and an endotoxin assay activity of ≥ 0.60 in 55 North American hospitals. This trial found no survival advantage among all participants or in the pre-specified subgroup with a multiorgan dysfunction score > 9. However, a post hoc assessment of patients without extreme endotoxemia [56] found a survival advantage on time to event analysis.

Finally, a new study called TIGRIS is currently under way in patients with endotoxemic septic shock (Clinical Trials.gov identifier: NCT03901807). This is a 150-patient prospective, multicenter, randomized, open-label trial of standard medical care plus the PMX versus standard medical care alone, for the treatment of subjects with endotoxemia (endotoxin activity ≥ 0.60 and < 0.90) and septic shock.

Non-selective hemoperfusion

Hemoperfusion with the CytoSorb® cartridge (CytoSorb®, Cytosorbents Inc, New Jersey, USA) represents a form of generic anti-inflammatory strategy and has been studied in case series and small comparative studies [57,58,59,60,61].

A multicenter randomized trial compared Cytosorb® therapy with conventional care [62] in 100 ventilated patients with sepsis or septic shock and either acute lung injury or ARDS. The primary outcome was the change in normalized interleukin-6 (IL-6) during study day 1 to 7. Although the CytoSorb® device had a single pass IL-6 extraction of between 5 and 18%, there were no significant differences in IL-6 levels.

More recently, CytoSorb®-based therapy was tested in COVID-19 patients on veno-venous extracorporeal membrane oxygenation (ECMO) [63]. In a single-center, open-label, randomized trial, 17 ECMO patients were treated with CytoSorb® for 72 h and 17 without. The decrease in IL-6 levels was similar but survival after 30 days was 18% with CytoSorb® therapy and 76% without (p = 0.0016). These mortality findings may represent a type 1 error in a small trial but raise concerns about the safety of this treatment in the setting of ECMO therapy.

Hemoperfusion with the JAFRON HA cartridge series (Jafron Biomedical, Guangdong, China) has been used in sepsis and reported in case series [64, 65]. One non-randomized study [66] involved 24 treated patients and 20 controls. It reported hemodynamic benefits, reduced interleukin 8 and 6 levels, and beneficial effects on ICU length of stay but no significant effect on mortality (46% in treated patients vs. 55% in control patients). Another study randomized 46 patients with acute lung injury and sepsis to daily treatment with the HA330 Jafron cartridge for three days vs usual care. HA-330 decreased TNF and IL-1 levels, improved markers of lung injury, duration of mechanical ventilation, CRRT and even 28-day mortality (67% in treated patients vs. 28% in control patients) [67]. In a third randomized trial of 30 patients, hemoperfusion with the same cartridge once a day was combined with pulse high-volume hemofiltration and was associated with beneficial effects on cytokines and cardiovascular physiology but no effect on mortality [68].

More recently, hemoperfusion with the Seraph® 100 Microbind® Affinity Blood Filter (ExThera, Martinez, CA) was approved by the FDA under Emergency Use Authorization for the treatment of severe COVID-19 [69]. This device contains adsorptive beads of ultrahigh molecular weight which, in vitro, remove the COVID-19 virus [70]. However, no randomized trials have yet been published [71].

Two randomized controlled studies of Cytosorb® have been published in 2022. The first studied hemoperfusion during cardiac surgery for infective endocarditis, with the device integrated into the cardiopulmonary bypass circuit [72]. It randomized 142 patients to Cytosorb® and 146 to usual care and found no differences in the primary outcome of change in SOFA score or in any other clinical outcomes, including mortality (21% vs. 22%). The second reported the effect of Cytosorb® therapy for 3 to 7 days in 50 COVID-19 patients with vasoplegic shock on time to resolution of shock [73]. It found no significant difference in this outcome and a mortality of 78% with Cytosorb® compared with 73% in the control arm.

Finally, in this review, we do not discuss the other techniques such as Molecular Adsorbent Recycling System (MARS) which provide a form of albumin adsorption treatment for liver disease. They do not represent direct hemoperfusion and are not strictly relevant to this review. Similarly, the use of hemofiltration membranes with greater adsorptive capacity (e.g., the oXiris membrane) does not constitute resin-based hemoperfusion and is also not directly relevant to this review.

The hemoperfusion research agenda and recommendations

New sorbent materials has now paved the way for a resurgence of research into the clinical application of hemoperfusion [74].

Initial reports in the treatment of chronic dialysis patients and of chronic liver patients with pruritus have been encouraging [49, 75]. At the same time, clinical applications of sorbents in sepsis, acute kidney injury, and other inflammatory states have provided useful data on feasibility and safety, forming the basis for future technical, procedural, and manufacturing optimization [58, 76, 77].

Given such early data, and the lack of consensus clinical practice guidelines, we recommend that research should first focus on achieving a better understanding of the basic aspects of the adsorption process, the properties of each sorbent, the mechanisms of adsorption, and their potential side effects [78]. Second, we recommend that ex vivo studies targeting multiple relevant solutes (e.g., cytokines, ammonia, possible uremic toxins, toxic drugs, antibiotics) should be conducted to establish their ex vivo clearance with varying blood flow and duration of perfusion to define optimal operating conditions. Third, we recommend focusing research on identifying meaningful target molecules and measuring their intra-corporeal and extracorporeal kinetics. This could be done by utilizing the creation of isotherms and by studying changes in cartridge adsorption over time. Fourth, we recommend that studies with similar multiple target should be conducted in large animals to assess biological and physiological effects on organ function with prolonged exposure.

In clinical research, first we recommend focusing on identifying what conditions should trigger hemoperfusion treatment and for how long. In this regard, we recommend that a hemoperfusion registry be set up to collect data as in ECMO registries. Second, we recommend focusing on defining adequate, optimal and safe dosage of hemoperfusion for different disorders. We should study how best to measure efficiency and efficacy, how many sessions should be prescribed, and how often hemoperfusion cartridges should be changed. Thus, we recommend that all future human hemoperfusion studies should report on performance characteristics (e.g., clearance, excretion ratio, mass removal, performance for key biological targets). Finally, we recommend exploring the move from intermittent (short treatment of a few hours) to continuous (24/7) hemoperfusion therapy in high-risk states (e.g., sepsis, acute liver failure, severe intoxication). Finally, in key target diseases and once the above elements have been addressed, we recommend the development of programs of investigation based on randomization (from pilot feasibility studies, to phase II, and ultimately phase III studies where appropriate).

Unless these studies are conducted, the role of hemoperfusion will remain uncertain and inadequately understood. This will likely have adverse consequence on both patients and the development of the science of blood purification. In many ways, hemoperfusion is where continuous renal replacement therapy (CRRT) was at its inception in the 1970s and 1980s. Clinicians and nurses prescribing and delivering CRRT in 2022 would barely be able to recognize their modern CRRT in the first reports of continuous arteriovenous hemofiltration. It is quite possible that, with hemoperfusion, future clinicians will be in a similar position.

Availability of data and materials

Not applicable.

References

  1. Ronco C, Ricci Z, Husain-Syed F. From multiple organ support therapy to extracorporeal organ support in critically ill patients. Blood Purif. 2019;48(2):99–105.

    Article  PubMed  Google Scholar 

  2. Ankawi G, Neri M, Zhang J, Breglia A, Ricci Z, Ronco C. Extracorporeal techniques for the treatment of critically ill patients with sepsis beyond conventional blood purification therapy: the promises and the pitfalls. Crit Care. 2018;22(1):262.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Clark WR, Ferrari F, La Manna G, Ronco C. Extracorporeal sorbent technologies: basic concepts and clinical application. Contrib Nephrol. 2017;190:43–57.

    Article  PubMed  Google Scholar 

  4. Ronco C, Bordoni V, Levin NW. Adsorbents: from basic structure to clinical application. Contrib Nephrol. 2002;137:158–64.

    Article  Google Scholar 

  5. La Greca G, Brendolan A, Ghezzi PM, et al. The concept of sorbents in hemodialysis. Int J Artif Organs. 1998;21:303–8.

    Article  PubMed  Google Scholar 

  6. Abe T, Uchita K, Orita H, et al. Effect of beta(2)-microglobulin adsorption column on dialysis-related amyloidosis. Kidney Int. 2003;64(4):1522–8.

    Article  PubMed  Google Scholar 

  7. Tetta C, Cavaillon JM, Camusi G, et al. Continuous plasma filtration coupled with sorbents. Kidney Int. 1998; 53(Suppl 66):S186–S189.11.

  8. Ronco C, Brendolan A, Winchester JF, et al. First clinical experience with an adjunctive hemoperfusion device designed specifically to remove β2-microglobulin in hemodialysis. Blood Purif. 2001;19:260–3.

    Article  CAS  PubMed  Google Scholar 

  9. Ferrari F, Clark WR, Ronco C: Sorbents: from basic structure to clinical application. In: Critical care Nephrology, Third Edition, Elsevier, 2019

  10. Lorenzin A, Neri M, de Cal M, Pajarin G, Mansi Montenegro G, Savastano S, Alghisi A, Ronco C. Fluid dynamics analysis by CT imaging technique of new sorbent cartridges for extracorporeal therapies. Blood Purif. 2019;48(1):18–24.

    Article  CAS  PubMed  Google Scholar 

  11. Sarti E, Chenet T, Stevanin C, Costa V, Cavazzini A, Catani M, Martucci A, Precisvalle N, Beltrami G, Pasti L. High-silica zeolites as sorbent media for adsorption and pre-concentration of pharmaceuticals in aqueous Solutions. Molecules. 2020;25(15):3331.

    Article  CAS  PubMed Central  Google Scholar 

  12. Ghannoum M, Bouchard J, Nolin TD, Ouellet G, Roberts DM. Hemoperfusion for the treatment of poisoning: technology, determinant of poison clearance, and application in clinical practice. Seminars Dial. 2014;27:350–61.

    Article  Google Scholar 

  13. Kawasaki CI, Nishi R, Uekihara. How tightly can a drug be bound to a protein and still be removal by charcoal hemoperfusion. In overdose cases. Clin Toxicol. 2005;43:95–99

  14. Redant S, DeBels D, Ismaili K, Honore PM. Membrane-based therapeutic plasma exchange in intensive care. Blood Purif. 2021;5:290–297.

  15. Sanchez AP, Balogun RA. Therapeutic plasma exchange in the critically ill: technology and indications. Adv Chronic Kidney Dis. 2021;28:59–73.

    Article  PubMed  Google Scholar 

  16. Redant S, De Bels D, Ismaili K, Honore P. Membrane-based therapeutic plasma exchange in intensive care. Blood Purif. 2021;50:290–7.

    Article  CAS  PubMed  Google Scholar 

  17. Chris-Olaiya A, Kapoor A, Ricci KC, Lindenmeyer CC. Therapeutic plasma exchange in liver failure. Worl J Hepatol. 2021;13:904–11.

    Article  Google Scholar 

  18. Moriyama K, Nishida O. Targeting cytokines, pathogen-associated molecular patterns and damage associated molecular patterns in sepsis via blood purification. Int J Mol Sci. 2021;22:8882.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Uchino S, Bellomo R, Goldsmith D, et al. Cytokine removal with a large pore cellulose triacetate filter: an ex vivo study. Int J Artif Organs. 2002;25(1):27–32.

    Article  CAS  PubMed  Google Scholar 

  20. Cole L, Bellomo R, Davenport P, et al. The effect of coupled haemofiltration and adsorption on inflammatory cytokines in an ex vivo model. Nephrol Dial Transplant. 2002;17(11):1950–6.

    Article  CAS  PubMed  Google Scholar 

  21. Cole L, Bellomo R, Davenport P, Tipping P, Ronco C. Cytokine removal during continuous renal replacement therapy: an ex vivo comparison of convection and diffusion. Int J Artif Organs. 2004;27(5):388–97.

    Article  CAS  PubMed  Google Scholar 

  22. Houschyar KS, Pyles MN, Rein S, et al. Continuous hemoadsorption with a cytokine adsorber during sepsis—a review of the literature Int J Artif Organs. 2017;40(5):205–211.

  23. Malard B, Lambert C, Kellum JA. In vitro comparison of the adsorption of inflammatory mediators by blood purification devices. Intensive Care Med Exp. 2018;6(1):12.

  24. Uchino S, Bellomo R, Morimatsu H, et al. Cytokine dialysis: an ex vivo study. ASAIO J. 2002;48(6):650–3.

    Article  CAS  PubMed  Google Scholar 

  25. Uchino S, Bellomo R, Goldsmith D, et al. Super high flux hemofiltration: a new technique for cytokine removal. Intensive Care Med. 2002;28(5):651–5.

    Article  CAS  PubMed  Google Scholar 

  26. Cole L, Bellomo R, Davenport P, Tipping P, Uchino S, Tetta C, Rono C. The effect of coupled haemofiltration and adsorption on inflammatory cytokines in an ex vivo model. Nephrol Dial Transplant. 2002;17(11):1950–6.

    Article  CAS  PubMed  Google Scholar 

  27. Scharf C, Schroeder I, Paal M, et al Can the cytokine adsorber CytoSorb help to mitigate cytokine storm and reduce mortality in critically ill patients? A propensity score matching analysis. Ann Intensive Care. 2021 22;11(1):115

  28. Ronco C, Tetta C, Mariano F, et al. Interpreting the mechanisms of continuous renal replacement therapy in sepsis: the peak concentration hypothesis. Artif Organs. 2003;27(9):792–801.

    Article  PubMed  Google Scholar 

  29. Roberts JA, Joynt GM, Lee A, et al. The effect of renal replacement therapy and antibiotic dose on antibiotic concentrations in critically ill patients: data from the multinational sampling antibiotics in renal replacement therapy study. Clin Infect Dis. 2021;72(8):1369–78.

    Article  CAS  PubMed  Google Scholar 

  30. Martin-Loeches I, Nunnally ME, et al. Surviving sepsis campaign: research opportunities for infection and blood purification therapies. Crit Care Explor. 2021;3(9): e0511.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Li X, Liu C, Mao Z, Qi S, Song R, Zhou F. Effectiveness of polymyxin B-immobilized hemoperfusion against sepsis and septic shock: a systematic review and meta-analysis. J Crit Care. 2021;63:187–95.

    Article  CAS  PubMed  Google Scholar 

  32. Rampino T, Gregorini M, Perotti L, et al. Hemoperfusion with CytoSorb as adjuvant therapy in critically ill patients with SARS-CoV2 pneumonia. Blood Purif. 2021;50(4–5):566–71.

    Article  CAS  PubMed  Google Scholar 

  33. Schädler D, Pausch C, Heise D, et al. The effect of a novel extracorporeal cytokine hemoadsorption device on IL-6 elimination in septic patients: a randomized controlled trial. PLoS ONE. 2017;12(10): e0187015.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  34. Sazonov V, Abylkassov R, Tobylbayeva Z, et al. Case Series: Efficacy and Safety of Hemoadsorption With HA-330 Adsorber in Septic Pediatric Patients With Cancer. Front Pediatr. 2021;9:67226.

    Article  Google Scholar 

  35. Pomarè Montin D, Ankawi G, et al. Biocompatibility and cytotoxic evaluation of new sorbent cartridges for blood hemoperfusion. Blood Purif. 2018;46(3):187–95.

    Article  PubMed  CAS  Google Scholar 

  36. Li WH, Yin YM, Chen H, Wang XD, Yun H, Li H, Luo J, Wang JW. Curative effect of neutral macroporous resin hemoperfusion on treating hemodialysis patients with refractory uremic pruritus. Medicine (Baltimore). 2017;96(12): e6160.

    Article  CAS  Google Scholar 

  37. Morachiello P, Landini S, Fracasso A, Righetto F, Scanferla F, Toffoletto P, Genchi R, Bazzato G. Combined hemodialysis-hemoperfusion in the treatment of secondary hyperparathyroidism of uremic patients. Blood Purif. 1991;9(3):148–52.

    Article  CAS  PubMed  Google Scholar 

  38. Kellum JA, Bellomo R, Mehta R, Ronco C. Blood purification in non-renal critical illness. Blood Purif. 2003;21(1):6–13.

    Article  PubMed  Google Scholar 

  39. Li Z, Wang G, Zhen G, Zhang Y, Liu J, Liu S. Effects of hemodialysis combined with hemoperfusion on severe acute pancreatitis. Turk J Gastroenterol. 2018;29(2):198–202.

    Article  PubMed  PubMed Central  Google Scholar 

  40. La Manna G, Donati G. Coupled plasma filtration adsorption: a multipurpose extracorporeal detoxification therapy. Blood Purif. 2018;46(3):228–38.

    Article  PubMed  CAS  Google Scholar 

  41. Wu M, Zhang H, Huang Y, Wu W, Huang J, Yan D. Efficiency of double plasma molecular absorption system on the acute severe cholestatic hepatitis. Blood Purif. 2021;50(6):876–82.

    Article  CAS  PubMed  Google Scholar 

  42. Rodeia SC, Martins FL, Fortuna P, Bento L. Cytokine adsorption therapy during extracorporeal membrane oxygenation in adult patients with COVID-19. Blood Purif. 2021;2:1–7.

    Google Scholar 

  43. Jung J, Eo E, Ahn KO. A case of hemoperfusion and L-carnitine management in valproic acid overdose. Am J Emerg Med. 2008;26(3):388.e3-4.

    Article  Google Scholar 

  44. Yang X, Xin S, Zhang Y, Li T. Early hemoperfusion for emergency treatment of carbamazepine poisoning. Am J Emerg Med. 2018;36(6):926–30.

    Article  PubMed  Google Scholar 

  45. Baylis S, Costa-Pinto R, Hodgson S, Bellomo R, Baldwin I.Combined Hemoperfusion and Continuous Veno-Venous Hemofiltration for Carbamazepine Intoxication. Blood Purif. 2021:1–5. Online ahead of print.

  46. Xiao Q, Wang W, Qi H, Gao X, et al. Continuous hemoperfusion relieves pulmonary fibrosis in patients with acute mild and moderate paraquat poisoning. J Toxicol Sci. 2020;45(10):611–7.

    Article  PubMed  Google Scholar 

  47. Bo L. Therapeutic efficacies of different hemoperfusion frequencies in patients with organophosphate poisoning. Eur Rev Med Pharmacol Sci. 2014;18(22):3521–3.

    CAS  PubMed  Google Scholar 

  48. Li Y, Qiu Z, Huang L, Cao C. Extracorporeal membrane oxygenation combined with sequential blood purification in the treatment of myocardial damage and cardiac arrest caused by mushroom poisoning. Toxicon. 2021;197:65–9.

    Article  CAS  PubMed  Google Scholar 

  49. Kittanamongkolchai W, El-Zoghby ZM, Eileen Hay J, et al. Charcoal hemoperfusion in the treatment of medically refractory pruritus in cholestatic liver disease. Hepatol Int. 2017;11(4):384–9.

    Article  PubMed  Google Scholar 

  50. Santoro A, Mancini E, Ferramosca E. Faenza S Liver support systems. Contrib Nephrol. 2007;156:396–404.

    Article  PubMed  Google Scholar 

  51. Magnani S, Atti M. Uremic toxins and blood purification: a review of current evidence and future perspectives. Toxins (Basel). 2021;13(4):246.

  52. Cruz DN, Perazella MA, Bellomo R, et al. Effectivness of polymyxin B-immobilized fiber column in sepsis: a systematic review. Crit Care. 2007;11:R47.

    Article  PubMed  PubMed Central  Google Scholar 

  53. Cruz DN, Antonelli M, Fumagalli R, et al. Early use of polymyxin B hemoperfusion in abdominal septic shock. JAMA. 2009;301:2445–52.

    Article  CAS  PubMed  Google Scholar 

  54. Payen D, Guilbert J, Launey Y, et al. Early use of polymyxin B hemoperfusion in patients with septic shock due to peritonitis: a multicentre randomized control trial. Intensive Care Med. 2015;41:975–84.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  55. Dellinger RP, Bagshaw SM, Antonelli M, et al. Effect of targeted polymyxin B hemoperfusion on 28-day mortality in patients with septic shock and elevated endotoxin level. JAMA. 2018;320(14):1455–63.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  56. Klein DJ, Foster D, Walker PM, Bagshaw SM, Mekonnen H. Antonelli M Polymyxin B hemoperfusion in endotoxemic septic shock patients without extreme endotoxemia: a post hoc analysis of the EUPHRATES trial. Intensive Care Med. 2018;44(12):2205–12.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  57. Nassiri AA, Hakemi MS, Miri MM, Shahrami R, Koomleh AA, Sabaghian T. Blood purification with CytoSorb in critically ill COVID-19 patients: a case series of 26 patients. Artif Organs. 2021;45(11):1338–47.

    Article  CAS  PubMed  Google Scholar 

  58. Boss K, Jahn M, Wendt D, Haidari Z, et al. Extracorporeal cytokine adsorption: Significant reduction of catecholamine requirement in patients with AKI and septic shock after cardiac surgery. PLoS ONE. 2021 8;16(2):e0246299.

  59. Paul R, Sathe P, Kumar S, Prasad S, Aleem M, Sakhalvalkar P. Multicentered prospective investigator initiated study to evaluate the clinical outcomes with extracorporeal cytokine adsorption device (CytoSorb) in patients with sepsis and septic shock. World J Crit Care Med. 2021;10(1):22–34.

    Article  PubMed  PubMed Central  Google Scholar 

  60. Alharthy A, Faqihi F, Memish ZA. Continuous renal replacement therapy with the addition of CytoSorb cartridge in critically ill patients with COVID-19 plus acute kidney injury: a case-series. Artif Organs. 2021;45(5):E101–12.

    Article  CAS  PubMed  Google Scholar 

  61. Brouwer WP, Duran S, Kuijper M. Ince C Hemoadsorption with CytoSorb shows a decreased observed versus expected 28-day all-cause mortality in ICU patients with septic shock: a propensity-score-weighted retrospective study. Crit Care. 2019;23(1):317.

    Article  PubMed  PubMed Central  Google Scholar 

  62. Schädler D, Pausch C, Heise D, et al The effect of a novel extracorporeal cytokine hemoadsorption device on IL-6 elimination in septic patients: A randomized controlled trial. PLoS One. 2017;12(10):e0187015.

  63. Supady A, Weber E, Rieder M, et al. Cytokine adsorption in patients with severe COVID-19 pneumonia requiring extracorporeal membrane oxygenation (CYCOV): a single centre, open-label, randomised, controlled trial. Lancet Respir Med. 2021;9(7):755–62.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  64. Esmaeili Vardanjani A, Ronco C, et al. Early hemoperfusion for cytokine removal may contribute to prevention of intubation in patients infected with COVID-19. Blood Purif. 2021;50(2):257–60.

    Article  CAS  PubMed  Google Scholar 

  65. Sazonov V, Abylkassov R, Tobylbayeva Z, Saparov A, Mironova O, Poddighe D. Case series: efficacy and safety of hemoadsorption with HA-330 adsorber in septic pediatric patients with cancer. Front Pediatr. 2021;9: 672260.

    Article  PubMed  PubMed Central  Google Scholar 

  66. Huang Z, Wang S, Su W, Liu J-Y. Removal of humoral mediators and the effect on the survival of septic patients by hemoperfusion with neutral microporous resin column. Ther Apher Dial. 2010;14:596–602.

  67. Huang Z, Wand S, Yang Z, Liu J. Effect on extrapulmonary sepsis-induced acute lung injury by hemoperfusion with neutral microporous resin column. Ther Apher Dial. 2013;17:454–61.

    Article  CAS  PubMed  Google Scholar 

  68. Chu L, Li G, Yu Y, et al. Clinical effects of hemoperfusion combined with pulse high-volume hemofiltration on septic shock. Medicine. 2020;99: e19058.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  69. Rifkin BS, Stewart IJ. Seraph-100 hemoperfusion in SARS-CoV-2-infected patients early in critical illness: a case series. Blood Purif 2021, July 14 Online ahead of print.

  70. Olson SW, Oliver JD, Collen J, et al. Treatment for severe coronavirus disease 2019 with the Seraph-100 microbind affinity blood filter. Crit Care Expl. 2020;2: e0180.

    Google Scholar 

  71. Schmidt JJ, Borchina DN, van’t Klooster M, et al. Interim analysis of the COSA (COVID-19 patients treated with the Seraph 100 Microbind Affinity filter) registry. Nepjhol Dial Transplant. 2021, Dec 7, Online ahead of print.

  72. Diab M, Lehmann T, Bothe W, et al. Cytokine hemoadsorption during cardiac surgery versus standard surgical care for infective endocarditis (REMOVE): results from a muylticenter, randomized, controlled trial. Circulation. 2022, Feb 25 Online ahead of print.

  73. Stockmannn H, Thelen P, Stroben F, et al. Cytosorb rescue for COVID-19 patients with vasoplegic shock and multiple organ failure: a prospective, open label, randomized controlled pilot study. Crit Care Med. 2022; Feb 9 [Online ahead of print].

  74. Ankawi G, Fan W, Pomarè Montin D, Lorenzin A, Neri M, Caprara C, de Cal M, Ronco C. A new series of sorbent devices for multiple clinical purposes: current evidence and future directions. Blood Purif. 2019;47(1–3):94–100.

    Article  PubMed  Google Scholar 

  75. Köhler T, Schwier E, Praxenthaler J, Kirchner C, Henzler D, Eickmeyer C. Therapeutic modulation of the host defense by hemoadsorption with CytoSorb®-Basics, indications and perspectives—a scoping review. Int J Mol Sci. 2021;22(23):12786.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  76. De Rosa S, Samoni S, Ronco C. Sequential extracorporeal therapy collaborative device and timely support for endotoxic, septic, and cardiac shock: a case Report. Blood Purif. 2020;49(4):502–8.

    Article  PubMed  Google Scholar 

  77. Tomescu D, Popescu M, David C, Dima S. Clinical effects of hemoadsorption with CytoSorb® in patients with severe acute pancreatitis: a case series. Int J Artif Organs. 2019;42(4):190–3.

    Article  CAS  PubMed  Google Scholar 

  78. Klinkmann G, Stope MB, Meyer A. Cytokine adsorption as a promising option for septic shock and multiple organ failure due to Candida infection and decompensated type 1 diabetes mellitus. Artif Organs. 2020;44(5):522–5.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

None.

Funding

The work related to this manuscript was not funded. However, it was supported in part by an unrestricted grant by Jafron Biomedical Co. Ltd.

Author information

Authors and Affiliations

Authors

Contributions

Both authors (CR and RB) contributed equally to the review of the literature and preparation of the manuscript. Both authors read and approved the final manuscript.

Corresponding author

Correspondence to Rinaldo Bellomo.

Ethics declarations

Ethical approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

Prof Claudio Ronco, in the last three years, has been consultant, medical advisor or part of the speaker bureau receiving fees from the following companies: Asahi Medical, Aferetica, Baxter, B.Braun, Biomerieux, Bioporto, Cytosorbents, ESTOR, Fresenius Medical Care, GE Healthcare, Jafron, Kaneka, Medica, Medtronic- Bellco, Nipro, Spectral, Toray Prof Rinaldo Bellomo, in the last three years, has been consultant, medical advisor or part of the speaker bureau receiving fees from the following companies: Baxter, BBraun, Jafron, Spectral, Bard, Endpoint, Notus, AM Pharma, Nutromics.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ronco, C., Bellomo, R. Hemoperfusion: technical aspects and state of the art. Crit Care 26, 135 (2022). https://doi.org/10.1186/s13054-022-04009-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13054-022-04009-w