Exp Clin Endocrinol Diabetes 2006; 114(7): 384-388
DOI: 10.1055/s-2006-924152
Article

J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York

Is the Frequency of Self-Monitoring of Blood Glucose Related to Long-Term Metabolic Control? Multicenter Analysis Including 24 500 Patients from 191 Centers in Germany and Austria

M. Schütt1 , W. Kern,2 , U. Krause3 , P. Busch,4 , A. Dapp5 , R. Grziwotz,6 , I. Mayer7 , J. Rosenbauer,8 , C. Wagner9 , A. Zimmermann,10 , W. Kerner11 , R. W. Holl3 , for the DPV initiative
  • 1Curschmann-Klinik, Timmendorfer Strand, Germany
  • 2Department of Internal Medicine I, University of Lübeck, Lübeck, Germany
  • 3University of Ulm, Department of Epidemiology, Ulm, Germany
  • 4SLK Kliniken Heilbronn GmbH, Klinikum Am Gesundbrunnen, Medizinische Klinik II, Heilbronn, Germany
  • 5Diabeteszentrum am Klinikum, Spaichingen, Germany
  • 6Dialysezentrum/Schwerpunktpraxis, Recklinghausen, Germany
  • 7Kreiskrankenhaus Rastatt, Rastatt, Germany
  • 8Institute for Biometrics and Epidemiology, German Diabetes Center at Heinrich Heine University, Düsseldorf, Germany
  • 9Diabetes-Schwerpunktpraxis, Saaldorf-Surheim, Germany
  • 10Diabetes-Schwerpunktpraxis, Bad Aibling, Germany
  • 11Heart and Diabetes Center Mecklenburg-Vorpommern, Department of Diabetes and Diseases of Metabolism, Karlsburg, Germany
Further Information

Publication History

Received: November 24, 2005 First decision: March 8, 2006

Accepted: March 30, 2006

Publication Date:
16 August 2006 (online)

Introduction

The increasing prevalence of diabetes mellitus and its long-term complications are associated with an expanding health care problem ([O'Brien et al., 2003]). This situation results in a more and more critical discussion regarding the cost effectiveness of clinically established tools that are used in diabetes care. A major concern in this debate that is primarily focused on the treatment of patients with type 2 diabetes is represented by the practice and frequency of self-monitoring of blood glucose (SMBG).

In the daily management of type 1 diabetes, SMBG is the recommended glycemic monitor that enables improved glycemic control. Maintaining blood glucose at or very near the normal range is known to decrease progression of microvascular disease in patients with type 1 diabetes ([The Diabetes Control and Complications Trial Research Group, 1993]), and the cost effectiveness of this policy has been reported using data from the diabetes control and complications trial ([Herman and Eastman, 1998]).

Evidence for the efficacy of SMBG in type 2 diabetic patients is, however, still conflicting ([Coster et al., 2000]; [Franciosi et al., 2005]), although some studies suggest improvement of metabolic control in type 2 diabetes using SMBG. The United Kingdom Prospective Diabetes Study showed that improved BG control decreases the frequency of new-onset microvascular complications and delays the progression of established microvascular complications in patients with type 2 diabetes ([UKPDS 33, 1998]). A subsequent cost effectiveness analysis revealed that the increased therapy costs of intensive blood glucose control are largely offset by significantly reduced costs of complications ([Gray et al., 2000]). Karter et al. demonstrated in a large observational study that frequent BG monitoring significantly improved HbA1c-levels in type 2 diabetic patients treated with insulin, oral antidiabetics, or diet only ([Karter et al., 2001]). Furthermore, a cohort study from the Veterans Administration showed improved glycemic control with lowered HbA1c in patients with insulin-treated type 2 diabetes who performed SMBG ([Murata et al., 2003]). A positive correlation between SMBG and the reduction of HbA1c-levels has also been described in two recent studies on non-insulin-treated patients ([Guerci et al., 2003]; [Schwedes et al., 2002]). Finally, in the latest guidelines on the management of type 2 diabetes, SMBG was recommended by the American Diabetes Association for glycemic monitoring ([American Diabetes Association, 2004]).

However, according to the cost-intensive factor of SMBG for the health care system, the optional daily glucometer strip utilization in diabetes care is still under debate ([Davidson, 2005]; [Ipp et al., 2005]). Here, we analyzed in an observational study whether the frequency of SMBG is related to long-term metabolic control by using anonymized data of 24 500 patients that were regularly transferred from 191 centers to a central computer-based database for quality management and documentation of diabetes in Germany (DPV-Wiss-database).

References

  • 1 American Diabetes Association . Tests of glycemia in diabetes.  Diabetes Care. 2004;  27 S91-S93
  • 2 Coster S, Gulliford M C, Seed P T, Powrie J K, Swaminathan R. Self-monitoring in type 2 diabetes mellitus: a meta-analysis.  Diabet Med. 2000;  17 755-761
  • 3 Davidson M B. Counterpoint: self-monitoring of blood glucose in type 2 diabetic patients not receiving insulin: a waste of money.  Diabetes Care. 2005;  28 1531-1533
  • 16 Franciosi M, Pellegrini F, de Berardis G. et al . Self-monitoring of blood glucose in non-insulin-treated diabetic patients: a longitudinal evaluation of its impact on metabolic control.  Diabet Med. 2005;  22 900-906
  • 4 Gray A, Raikou M, McGuire A, Fenn P, Stevens R, Cull C, Stratton I, Adler A, Holman R, Turner R. Cost effectiveness of an intensive blood glucose control policy in patients with type 2 diabetes: economic analysis alongside randomised controlled trial (UKPDS 41). United Kingdom Prospective Diabetes Study Group.  BMJ. 2000;  320 1373-1378
  • 5 Guerci B, Drouin P, Grange V, Bougneres P, Fontaine P, Kerlan V, Passa P, Thivolet C, Vialettes B, Charbonnel B, Group A SIA. Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) Study.  Diabetes Metab. 2003;  29 587-594
  • 6 Herman W H, Eastman R C. The effects of treatment on the direct costs of diabetes.  Diabetes Care. 1998;  21 C19-C24
  • 7 Ipp E, Aquino R L, Christenson P. Point: self-monitoring of blood glucose in type 2 diabetic patients not receiving insulin: the sanguine approach.  Diabetes Care. 2005;  28 1528-1530
  • 8 Karter A J, Ackerson L M, Darbinian J A. et al . Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes Registry.  Am J Med. 2001;  111 1-9
  • 9 Martin S, Schneider B, Heinemann L, Lodwig V, Kurth H J, Kolb H, Scherbaum W A. Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study.  Diabetologia. 2006;  49 271-278
  • 10 Murata G H, Shah J H, Hoffman R M, Wendel C S, Adam K D, Solvas P A, Bokhari S U, Duckworth W C. Diabetes Outcomes in Veterans Study (DOVES) . Intensified blood glucose monitoring improves glycemic control in stable, insulin-treated veterans with type 2 diabetes: the Diabetes Outcomes in Veterans Study (DOVES).  Diabetes Care. 2003;  26 1759-1763
  • 11 O'Brien J A, Patrick A R, Caro J. Estimates of direct medical costs for microvascular and macrovascular complications resulting from type 2 diabetes mellitus in the United States in 2000.  Clin Ther. 2003;  25 1017-1038
  • 12 Schwedes U, Siebolds M, Mertes G. SMBG Study Group . Meal-related structured self-monitoring of blood glucose: effect on diabetes control in non-insulin-treated type 2 diabetic patients.  Diabetes Care. 2002;  25 1928-1932
  • 13 The Diabetes Control and Complications Trial Research Group . The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.  N Engl J Med. 1993;  329 977-986
  • 14 UKPDS Group . Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33).  Lancet. 1998;  352 837-853
  • 15 Welschen L M, Bloemendal E, Nijpels G, Dekker J M, Heine R J, Stalman W A, Bouter L M. Self-monitoring of blood glucose in patients with type 2 diabetes who are not using insulin.  Cochrane Database Syst Rev. 2005;  CD005060

Prof. Dr. med. W. Kern

Universitätsklinikum Schleswig-Holstein, Campus Lübeck
Medizinische Klinik I

Ratzeburger Allee 160

23538 Lübeck

Germany

Phone: + 49 451 500 22 46

Fax: + 49 451 500 29 38

Email: kern@kfg.uni-luebeck.de

    >