Inappropriate Implantable Cardioverter Defibrillator Shock from a Transcutaneous Muscle Stimulation Device Therapy

  • Case Report
  • Published:
Journal of Interventional Cardiac Electrophysiology Aims and scope Submit manuscript

Abstract

Inappropriate shock from implantable cardioverter defibrillator (ICD) may result from external electromagnetic interference (EMI), especially for unipolar ventricle sensing. Previous case reports and small in-vitro safety study suggested that endocardial bipolar lead system may be immune from EMI resulting from transcutaneous electrical neuromuscle stimulation (TENS) therapy. This report presents an unusual case of inappropriate discharge in a patient with ICD of endocardial bipolar lead system, receiving TENS from a commercially available device.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Rosenqvist M, Beyer T, Block M, den Dulk K, Minten J, Lindemans F. Adverse events with transvenous implantable cardioverter defibrillators. A prospective multicenter study. Circulation 1998;98:663–670.

    CAS  PubMed  Google Scholar 

  2. Ruppel R, Schluter C, Boczor S, Meinertz T, Schluter M, Kuck KH, Cappato R. Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: Experience from stored electrograms of implantable cardioverter defibrillators. J Am Coll Cardiol 1998;32:1724–1730.

    Article  CAS  PubMed  Google Scholar 

  3. Glotzer TV, Gordon M, Sparta M, Radoslovich G, Zimmerman J. Electromagnetic interference from a muscle stimulation device causing discharge of an implantable cardiovertor defibrillator: Epicardial bipolar and endocardial bipolar sensing circuits are compared. Pacing Clin Electrophysiol 1998;21(10):1996–1998.

    CAS  PubMed  Google Scholar 

  4. Crevenna R, Stix G, Pleiner J, Pezawas T, Schmidinger H, Quittan M, Wolzt M. Electromagnetic interference by transcutaneous neuromuscular electrical stimulation inpatients with bipolar sensing implantable cardioverter defibrillators: A pilot safety study. PACE 2003;26(1):626–629.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chu-Pak Lau MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Siu, CW., Tse, HF. & Lau, CP. Inappropriate Implantable Cardioverter Defibrillator Shock from a Transcutaneous Muscle Stimulation Device Therapy. J Interv Card Electrophysiol 13, 73–75 (2005). https://doi.org/10.1007/s10840-005-0357-3

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10840-005-0357-3

Navigation