J Hand Microsurg 2009; 01(01): 45-49
DOI: 10.1007/s12593-009-0008-5
Point of Technique
Thieme Medical and Scientific Publishers Private Ltd.

Internal headless compression screw method for 4-corner fusion

Mark Henry

Subject Editor:
Further Information

Publication History

12 February 2009

13 March 2009

Publication Date:
02 September 2016 (online)

Abstract

Midcarpal fusion and scaphoidectomy, also referred to as 4 corner fusion, is a common treatment for post-traumatic wrist arthritis, either scapholunate advanced collapse or scaphoid nonunion advanced collapse. Historically fixation for the fusion mass was performed with Kirschner wires. Bone graft was sometimes taken from the discarded scaphoid. More recently, articles have focused on the method of fixation and its potential role in causing high nonunion rates or specific complications. This article offers readers a reliable technique for midcarpal fusion designed to minimize both nonunion and hardware related complications.

 
  • References

  • 1 Chung KC, Watt AJ, Kotsis SV. A prospective outcomes study of four-corner wrist arthrodesis using a circular limited wrist fusion plate for stage II scapholunate advanced collapse wrist deformity. Plast Reconstr Surg 2006; 118: 433-442
  • 2 Dacho A, Grundel J, Holle G et al Long-term results of midcarpal arthrodesis in the treatment of scaphoid nonunion advanced collapse (SNAC-wrist) and scapholu-nate advanced collapse (SLAC-wrist). Ann Plast Surg 2006; 56: 139-144
  • 3 Vance MC, Hernandez JD, Didonna M et al Complications and outcome of four-corner arthrodesis: circular plate fixation versus traditional techniques. J Hand Surg (Am) 2005; 30: 1122-1127
  • 4 Sauerbier M, Trankle M, Linsner G et al Midcarpal arthrodesis with complete scaphoid excision and interposition bone graft in the treatment of advanced carpal collapse (SNAC/SLAC wrist): operative technique and outcome assessment. J Hand Surg BR 2000; 25: 341-345
  • 5 Calandruccio JH, Gelberman RH, Duncan SF et al Capitolunate arthrodesis with scaphoid and triquetrum excision. J Hand Surg (AM) 2000; 25: 824-832
  • 6 Wyrick JD, Stern PJ, Kiefhaber TR. Motionpreserving procedures in the treatment of scapholunate advanced collapse wrist: proximal row carpectomy versus four-corner arthrodesis. J Hand Surg (Am) 1995; 20: 965-970
  • 7 Cohen MS, Kozin SH. Degenerative arthritis of the wrist: proximal row carpectomy versus scaphoid excision and four-corner arthrodesis. J Hand Surg (Am) 2001; 26: 94-104
  • 8 Dacho AK, Baumeister S, Germann G. Comparison of proximal row carpectomy and midcarpal arthrodesis for the treatment of scaphoid nonunion advanced collapse (SNAC-wrist) and scapholunate advanced collapse (SLAC-wrist) in stage II. J Plast Reconstr Aesthet Surg 2008; 61: 1210-1218
  • 9 Shindle MK, Burton KJ, Weiland AJ et al Complications of circular plate fixation for four-corner arthrodesis. J Hand Surg (E) 2007; 32: 50-53
  • 10 Kirschenbaum D, Schneider LH, Kirkpatrick WH et al Scaphoid excision and capitolunate arthrodesis for radioscaphoid arthritis. J Hand Surg (Am) 1993; 18: 780-785
  • 11 Rodgers JA, Holt G, Finnerty EP. Scaphoid excision and limited wrist fusion: a comparison of K-wire and circular plate fixation. Hand 2008; 3: 276-281
  • 12 Merrell GA, McDermott EM, Weiss AP. Four-corner arthrodesis using a circular plate and distal radius bone grafting: a consecutive case series. J Hand Surg (Am) 2008; 33: 635-642
  • 13 Ekelund L, Hagberg L, Horberg L et al Imaging of four-corner fusion (SLAC arthrodesis) of the wrist with 64-slice computed tomography. Acta Radiol 2007; 48: 76-79
  • 14 El-Mowafi H, El-Hadidi M, Boghdady GW et al Functional outcome of four-corner arthrodesis for treatment of grade IV scaphoid non-union. Acta Orthop Belg 2007; 73: 604-611
  • 15 Goubier JN, Teboul F. Capitolunate arthrodesis with compression screws. Tech Hand Up Extrem Surg 2007; 11: 24-28
  • 16 Van Riet RP, Bain GI. Three-corner wrist fusion using memory staples. Tech Hand Up Extrem Surg 2006; 10: 259-264
  • 17 Ronchetti PJ, Topper SM. Lunocapitate fusion using the OSStaple compression staple. Tech Hand Up Extrem Surg 2006; 10: 231-234