Skip to main content
Erschienen in: European Surgery 5/2016

01.10.2016 | review article

Surgical use of fibrin glue-coated collagen patch for non-hemostatic indications

A review

verfasst von: Dimitrios Sampanis, MD, PhD, Maria Siori, MD, PhD

Erschienen in: European Surgery | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Summary

TachoSil and its predecessor products, TachoComb and TachoComb H, have been extensively used in a variety of multidisciplinary surgical settings since being introduced in the early 1990s. However, to date, TachoSil remains the first and only dual action patch for general tissue sealing and is frequently used in variety of surgical indications other than haemostasis. Classically, TachoSil is indicated for improvement of haemostasis. However, there is recently some evidence suggesting that it can be successfully used in promoting tissue healing, which could be useful in various non-hemostatic indications. TachoSil is safe and well tolerated, with occurrence of adverse events similar in TachoSil and non-TachoSil treated patients in controlled trials. The clinical implications of such an approach are obvious. Despite its cost, potential benefits could easily translate into cost savings due to avoidance of complications and to reduction of duration of hospital stay. Existing data are limited and further randomized controlled studies are needed to accurately establish the role of TachoSil for non-hemostatic indications in a variety of surgical indications, such as in abdominal and gastrointestinal surgery, pulmonary surgery, cardiothoracic surgery, renal surgery, gynecology, neurosurgery and more.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Erb MA, Thomas C, Hartrumpf M, et al. The use of TachoSil surgical patch or fibrin glue in coronary artery surgery does not affect quality of anastomosis or provoke postoperative adhesions in pigs. Eur J Cardiothorac Surg. 2009;36:703–7.CrossRefPubMed Erb MA, Thomas C, Hartrumpf M, et al. The use of TachoSil surgical patch or fibrin glue in coronary artery surgery does not affect quality of anastomosis or provoke postoperative adhesions in pigs. Eur J Cardiothorac Surg. 2009;36:703–7.CrossRefPubMed
2.
Zurück zum Zitat Aziz O, Athanasiou T, Darzi A. Haemostasis using a ready-to-use collagen sponge coated with activated thrombin and fibrinogen. Surg Technol Int. 2005;14:35–40.PubMed Aziz O, Athanasiou T, Darzi A. Haemostasis using a ready-to-use collagen sponge coated with activated thrombin and fibrinogen. Surg Technol Int. 2005;14:35–40.PubMed
3.
Zurück zum Zitat Erdogan D, Graaf W de, Gulik TM van. Adhesive strength of fibrinogen-coated collagen patch or liquid fibrin sealant in an experimental liver resection model in pigs. Eur Surg Res. 2008;41:298–302.CrossRefPubMed Erdogan D, Graaf W de, Gulik TM van. Adhesive strength of fibrinogen-coated collagen patch or liquid fibrin sealant in an experimental liver resection model in pigs. Eur Surg Res. 2008;41:298–302.CrossRefPubMed
4.
Zurück zum Zitat Carbon RT, Lewandrowski K‑U, Wise DL, Trantolo DJ, Gresser JD, Yaszemski MJ, Altobelli DE. (editors) Evaluation of biodegradable fleece-bound sealing: history, material science, and clinical application in tissue engineering and biodegradable equivalents. New York: Marcel Dekker; 2002., pp 587–650. Carbon RT, Lewandrowski K‑U, Wise DL, Trantolo DJ, Gresser JD, Yaszemski MJ, Altobelli DE. (editors) Evaluation of biodegradable fleece-bound sealing: history, material science, and clinical application in tissue engineering and biodegradable equivalents. New York: Marcel Dekker; 2002., pp 587–650.
5.
Zurück zum Zitat Berdazjs D, Burki M, Michelis A, Segesser LK von. Seal properties of Tachosil: in vitro hemodynamic measurements. Interact Cardiovasc Thorac Surg. 2010;10(6):910–3.CrossRef Berdazjs D, Burki M, Michelis A, Segesser LK von. Seal properties of Tachosil: in vitro hemodynamic measurements. Interact Cardiovasc Thorac Surg. 2010;10(6):910–3.CrossRef
6.
Zurück zum Zitat Haas S. The use of a surgical patch coated with human coagulation factors in surgical routine. Clin Appl Thromb Hemost. 2006;12:445–50.CrossRefPubMed Haas S. The use of a surgical patch coated with human coagulation factors in surgical routine. Clin Appl Thromb Hemost. 2006;12:445–50.CrossRefPubMed
7.
Zurück zum Zitat Toti L, Attia M, Mangia TM, et al. Reduction in bile leaks following adult split liver transplant using a fibrin-collagen sponge: a pilot study. Dig Liver Dis. 2010;42:205–9.CrossRefPubMed Toti L, Attia M, Mangia TM, et al. Reduction in bile leaks following adult split liver transplant using a fibrin-collagen sponge: a pilot study. Dig Liver Dis. 2010;42:205–9.CrossRefPubMed
8.
Zurück zum Zitat Chirletti P, Carona R, Fanello G, et al. Pangreaticojejunostomy with application of fibrinogen/thrombin-coated collagen patch(Tachosil) in Roux-en-y reconstruction after pangreaticoduodenectomy. J Gastrointest Surg. 2009;13:1396–8.CrossRefPubMed Chirletti P, Carona R, Fanello G, et al. Pangreaticojejunostomy with application of fibrinogen/thrombin-coated collagen patch(Tachosil) in Roux-en-y reconstruction after pangreaticoduodenectomy. J Gastrointest Surg. 2009;13:1396–8.CrossRefPubMed
9.
Zurück zum Zitat Tagliabue TF, Angelo DC, Zuccon W, et al. Use of Tachosil in splenectomy in patients with clotting and blood composition disorders. Minerva Chir. 2007;62(1):73–8.PubMed Tagliabue TF, Angelo DC, Zuccon W, et al. Use of Tachosil in splenectomy in patients with clotting and blood composition disorders. Minerva Chir. 2007;62(1):73–8.PubMed
10.
Zurück zum Zitat Carbon RT, Baar S, Waldschmidt J, et al. Innovative minimally invasive pediatric surgery is of therapeutic value for splenic injury. J Pediatr Surg. 2002;37:1146–50.CrossRefPubMed Carbon RT, Baar S, Waldschmidt J, et al. Innovative minimally invasive pediatric surgery is of therapeutic value for splenic injury. J Pediatr Surg. 2002;37:1146–50.CrossRefPubMed
11.
Zurück zum Zitat Schwaitzberg SD, Chan MW, Cole DJ, et al. Comparison of poly-N-acetyl glucosamine with commercially available topical hemostats for achieving hemostasis in coagulopathic models of splenic hemorrhage. J Trauma. 2004;57:S29–32.CrossRefPubMed Schwaitzberg SD, Chan MW, Cole DJ, et al. Comparison of poly-N-acetyl glucosamine with commercially available topical hemostats for achieving hemostasis in coagulopathic models of splenic hemorrhage. J Trauma. 2004;57:S29–32.CrossRefPubMed
12.
Zurück zum Zitat Di Carlo DI, Pulvirenti E, Toro A. Use of a fibrinogen- and thrombin-coated patch for peptic ulcer perforation repair. Hepatogastroenterology. 2009;56(91–92):575–7.PubMed Di Carlo DI, Pulvirenti E, Toro A. Use of a fibrinogen- and thrombin-coated patch for peptic ulcer perforation repair. Hepatogastroenterology. 2009;56(91–92):575–7.PubMed
13.
Zurück zum Zitat Erdogan A, Gurses G, Keskin H, Dermircan A. The sealing effect of a fibrin tissue patch on the esophageal perforation area in the primary repair. World J Surg. 2007;31:2199–203.CrossRefPubMed Erdogan A, Gurses G, Keskin H, Dermircan A. The sealing effect of a fibrin tissue patch on the esophageal perforation area in the primary repair. World J Surg. 2007;31:2199–203.CrossRefPubMed
14.
Zurück zum Zitat Romer J, Sorensen M. Sealing of gastrointestinal anastomoses with a fibrin glue-coated collagen patch: a safety study. J Investig Surg. 2007;20:363–9.CrossRef Romer J, Sorensen M. Sealing of gastrointestinal anastomoses with a fibrin glue-coated collagen patch: a safety study. J Investig Surg. 2007;20:363–9.CrossRef
15.
Zurück zum Zitat Erdogru T, Sanli A, Celik O, Baykara M. Laparoscpic transvesical repair of recurrent vesicovaginal fistula using with fleece-bound sealing system. Arch Gynecol Obstet. 2008;277(5):461–4.CrossRefPubMed Erdogru T, Sanli A, Celik O, Baykara M. Laparoscpic transvesical repair of recurrent vesicovaginal fistula using with fleece-bound sealing system. Arch Gynecol Obstet. 2008;277(5):461–4.CrossRefPubMed
16.
Zurück zum Zitat Rubio Briones JJ, Estébanez Zarranz J, Domínguez Escrig JL. Role of laparoscopy in the presence of a renal mass under 4 cm in size. Actas Urol Esp. 2009;33(5):534–43.CrossRefPubMed Rubio Briones JJ, Estébanez Zarranz J, Domínguez Escrig JL. Role of laparoscopy in the presence of a renal mass under 4 cm in size. Actas Urol Esp. 2009;33(5):534–43.CrossRefPubMed
17.
Zurück zum Zitat Czerny M, Fleck T, Salat A, et al. Sealing of the mediastinum with a local hemostyptic agent reduces chest tube duration after complete mediastinal lymph node dissection for stage I and II non-small cell lung carcinoma. Ann Thorac Surg. 2004;77:1028–32.CrossRefPubMed Czerny M, Fleck T, Salat A, et al. Sealing of the mediastinum with a local hemostyptic agent reduces chest tube duration after complete mediastinal lymph node dissection for stage I and II non-small cell lung carcinoma. Ann Thorac Surg. 2004;77:1028–32.CrossRefPubMed
18.
Zurück zum Zitat Lang G, Csekeo A, Stamatis G, et al. Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy. Eur J Cardiothorac Surg. 2004;25:160–6.CrossRefPubMed Lang G, Csekeo A, Stamatis G, et al. Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy. Eur J Cardiothorac Surg. 2004;25:160–6.CrossRefPubMed
19.
Zurück zum Zitat Higashiyama M, Takami K, Higaki N, Kodama K. Pulmonary middle lobe fixation using TachoComb in patients undergoing right upper lobectomy with complete oblique fissure. Interact Cardiovasc Thorac Surg. 2004;3:107–9.CrossRefPubMed Higashiyama M, Takami K, Higaki N, Kodama K. Pulmonary middle lobe fixation using TachoComb in patients undergoing right upper lobectomy with complete oblique fissure. Interact Cardiovasc Thorac Surg. 2004;3:107–9.CrossRefPubMed
20.
Zurück zum Zitat Muramatsu T, Ohmori K, Shimamura M, et al. Staple line reinforcement with fleece-coated fibrin glue (TachoComb) after thoracoscopic bullectomy for the treatment of spontaneous pneumothorax. Surg Today. 2007;37:745–9.CrossRefPubMed Muramatsu T, Ohmori K, Shimamura M, et al. Staple line reinforcement with fleece-coated fibrin glue (TachoComb) after thoracoscopic bullectomy for the treatment of spontaneous pneumothorax. Surg Today. 2007;37:745–9.CrossRefPubMed
21.
Zurück zum Zitat Takanami I. Closure of a bronchopleural fistula using a fibrin-glue coated collagen patch. Interact Cardiovasc Thorac Surg. 2003;2:387–8.CrossRefPubMed Takanami I. Closure of a bronchopleural fistula using a fibrin-glue coated collagen patch. Interact Cardiovasc Thorac Surg. 2003;2:387–8.CrossRefPubMed
22.
Zurück zum Zitat Anegg U, Lindenmann J, Matzi V, et al. Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery. Eur J Cardiothorac Surg. 2007;31:198–202.CrossRefPubMed Anegg U, Lindenmann J, Matzi V, et al. Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery. Eur J Cardiothorac Surg. 2007;31:198–202.CrossRefPubMed
23.
Zurück zum Zitat Renaa O, Papaliaa E, Mineo TC, et al. Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease. Interact Cardiovasc Thorac Surg. 2009;9:973–7.CrossRef Renaa O, Papaliaa E, Mineo TC, et al. Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease. Interact Cardiovasc Thorac Surg. 2009;9:973–7.CrossRef
24.
Zurück zum Zitat Bajardi G, Pecocaro F, Mirabela D. Efficacy of TachoSil patches in controlling Dacron suture-hole bleeding after abdominal aortic aneurysm open repair. J Cardiothorac Surg. 2009;4:60 doi:10.1186/1749-8090-4-60.CrossRefPubMedPubMedCentral Bajardi G, Pecocaro F, Mirabela D. Efficacy of TachoSil patches in controlling Dacron suture-hole bleeding after abdominal aortic aneurysm open repair. J Cardiothorac Surg. 2009;4:60 doi:10.1186/1749-8090-4-60.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Berger A, Tempfer C, Hartmann B, et al. Sealing of postoperative axillary leakage after axillary lymphadenectomy using a fibrin glue coated collagen patch: a prospective randomised study. Breast Cancer Res Treat. 2001;67:9–14.CrossRefPubMed Berger A, Tempfer C, Hartmann B, et al. Sealing of postoperative axillary leakage after axillary lymphadenectomy using a fibrin glue coated collagen patch: a prospective randomised study. Breast Cancer Res Treat. 2001;67:9–14.CrossRefPubMed
26.
Zurück zum Zitat Attar KH, Jaya Namasivayam, Green J, et al. Kidney Salvage Using the Fibrinogen- and Thrombin-Coated Sponge TachoSil During Nephron-Sparing Surgery for the Resection of Large Renal Tumours. Ann R Coll Surg Engl. 2008;90(5):405.CrossRef Attar KH, Jaya Namasivayam, Green J, et al. Kidney Salvage Using the Fibrinogen- and Thrombin-Coated Sponge TachoSil During Nephron-Sparing Surgery for the Resection of Large Renal Tumours. Ann R Coll Surg Engl. 2008;90(5):405.CrossRef
27.
Zurück zum Zitat Siemer S. Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumor resection. Eur Urol. 2007;52(4):1156–63.CrossRefPubMed Siemer S. Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumor resection. Eur Urol. 2007;52(4):1156–63.CrossRefPubMed
28.
Zurück zum Zitat Simonato A, Varca V, Esposito M, Venzano F, et al. The use of a surgical patch in the prevention of lymphoceles after extraperitoneal pelvic lymphadenectomy for prostate cancer. J Urol. 2009;182(5):2285–90.CrossRefPubMed Simonato A, Varca V, Esposito M, Venzano F, et al. The use of a surgical patch in the prevention of lymphoceles after extraperitoneal pelvic lymphadenectomy for prostate cancer. J Urol. 2009;182(5):2285–90.CrossRefPubMed
29.
Zurück zum Zitat Tamasauskas A, Sinkunas K, Draf W, et al. Management of cerebrospinal fluid leak after surgical removal of pituitary adenomas. Medicina (Kaunas). 2008;44(4):302–7. Tamasauskas A, Sinkunas K, Draf W, et al. Management of cerebrospinal fluid leak after surgical removal of pituitary adenomas. Medicina (Kaunas). 2008;44(4):302–7.
30.
Zurück zum Zitat Birth M, Figueras J, Bernardini S, et al. Collagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study. Patient Saf Surg. 2009;3:13.CrossRefPubMedPubMedCentral Birth M, Figueras J, Bernardini S, et al. Collagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study. Patient Saf Surg. 2009;3:13.CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Kotzea PG, et al. Human fibrinogen and thrombin patch for extraluminal protection of intestinal anastomosis. J Coloproctol (rio J). 2013;33(3). Kotzea PG, et al. Human fibrinogen and thrombin patch for extraluminal protection of intestinal anastomosis. J Coloproctol (rio J). 2013;33(3).
Metadaten
Titel
Surgical use of fibrin glue-coated collagen patch for non-hemostatic indications
A review
verfasst von
Dimitrios Sampanis, MD, PhD
Maria Siori, MD, PhD
Publikationsdatum
01.10.2016
Verlag
Springer Vienna
Erschienen in
European Surgery / Ausgabe 5/2016
Print ISSN: 1682-8631
Elektronische ISSN: 1682-4016
DOI
https://doi.org/10.1007/s10353-016-0436-y

Weitere Artikel der Ausgabe 5/2016

European Surgery 5/2016 Zur Ausgabe

original article

Hepatic hydatid cysts